STEP 2:  Mount the EWR Regulator

The EWR Regulator has the flexibility to be mounted wherever it makes the most sense for your 

application. A few guidelines to consider:

 

The EWR should be mounted on a stable location away from welding sparks or places 

where it can be damaged.

 

The current measuring cable, gas hoses, and power supply cable must have easy, bind-

free access to their respective connectors on the regulator.

 

Mounting location for optimum performance of EWR is between 6 to 30 feet behind the 

solenoid on your wire feeder.  Ideal location for robotic installations is on the pedestal at 

the base of the robot.  Semi-automatic and Manual applications can vary as noted.  Refer 

to Steps 5, 7, and 8 for additional information on hose lengths and tuning of system.

EWR Basic shown

STEP 3:  Shunt Installation

 

Pass either the work or electrode cable through the shunt and affix the shunt onto a stable 

location.

 

Route the shunt connection cable back to the EWR. Secure the shunt connection cable 

utilizing non-conductive fasteners and ties. Ensure the shunt cable is not damaged. 

Do 

not coil any excess cable.

 

Connect the shunt measuring cable to the EWR or EWR Pro regulator box.

Note:  Do not have any part of the shunt cable in close proximity to or in contact with any 

electrically charged cord, as this will give a false current signal to the regulator.

Summary of Contents for EWR

Page 1: ...EWR Quick Install Instructions www binzel abicor com TECHNOLOGY FOR THE WEL DER S WO RL D...

Page 2: ...4 5 Inventory Checklist 1 Warranty 2 Guarantee 3 Calibration Report 4 Safety Documentation 5 Operating Instructions 6 EWR or EWR Pro Basic Model shown 7 110v AC Power Supply 8 Current Measuring Shunt...

Page 3: ...s on the pedestal at the base of the robot Semi automatic and Manual applications can vary as noted Refer to Steps 5 7 and 8 for additional information on hose lengths and tuning of system EWR Basic s...

Page 4: ...egulator here Attach one end of the gas hose to the right gas barb of the regulator Route the gas hose to the feeder to ensure that the hose will not be exposed to pinching binding or damage Ensure ho...

Page 5: ...ty of welding applications There are five schedules that provide a greater volume of delivery than the factory default and five schedules that provide less volume than the factory default The illumina...

Page 6: ...eptable this procedure is completed and you can move on to Step 8 If the weld still is not acceptable repeat the procedure until an acceptable weld is achieved then move on to Step 8 STEP 8 Setting th...

Page 7: ...r 4 Press and hold the ON OFF button until the lights make a quick flash The flash confirms the new setting is saved and the EWR returns to normal mode of operation APPENDIX BINZEL EWR Part Numbers Pa...

Page 8: ...n 650 Medimmune Court Suite 110 Frederick MD 21703 Phone 1 800 542 4867 Fax 1 301 846 4497 Email customerservice abicorusa com Gas Flow Rate in Relation to EWR Setting L Min Ampere Usage Gas Flow Meas...

Reviews: