CR1000/CR1250
6 Putting into operation
EN - 15
6.3 Before initially putting into operation
1
Connect the coolant hoses.
2
Open the screw cap
on the filler neck
of the coolant container
3
Fill the cooling unit with
ABICOR BINZEL
BTC coolant up to the maximum fill level mark on the
container. Do not close the filler neck.
4
Switch on the cooling unit.
5
Fill the cooling unit at the filler neck
of the coolant container
with
ABICOR BINZEL
BTC coolant
up to the maximum fill level mark on the container.
6
Repeat this procedure approx. 2-3 times until the cooling liquid is distributed throughout the entire coolant
circuit and the maximum fill level has been reached.
7
Close the filler neck
with the screw cap
1
Coolant supply (blue)
2
Screw cap
3
Filler neck
4
Coolant container
5
Outlet neck
6
Coolant return (red)
Fig. 7
Front/rear
1
6
2
3
4
5
CAUTION
Damage caused by unsuitable and conductive cooling liquids is not covered by the
warranty.
• Prior to refilling the cooling system with BTC coolant, the system must be rinsed with clean water to
remove any residues.
• If other cooling liquids are used, they must not contain any aggressive, abrasive or resinous
components.
• If
ABICOR BINZEL
BTC coolant is not available, deionized water (permitted operating temperature
+5°C to +40°C) or, after cleaning the device, a mixture of 25% monoethylene glycol and 75%
deionized water (permitted operating temperature -10°C to +40°C) can be used.
Summary of Contents for CR1000
Page 29: ...CR1000 CR1250 13 Anhang DE 29 ...
Page 57: ...CR1000 CR1250 13 Appendix EN 29 ...
Page 113: ...CR1000 CR1250 14 Notizen Notes Notes Notas ES 29 14 Notizen Notes Notes Notas ...
Page 114: ...ES 30 14 Notizen Notes Notes Notas CR1000 CR1250 ...
Page 115: ...CR1000 CR1250 14 Notizen Notes Notes Notas ES 31 ...