EN - 8
3 Product description
CR1000/CR1250
3.2 Abbreviations
CR1000
CR1250
Heat exchanger
2-row
3-row
Supply voltage
115/230VAC 50/60Hz
Cooling capacity
1000 W with H
2
O
1250 W with H
2
O
Q = 1 l/min at +25 °C
750 W with BTC-15
1050 W with BTC-15
Max. delivery height
Approx. 35 m 230V
Max. pump capacity
7.0 l/min
Max. coolant outlet pressure/pump pressure
3.5 bar
Pump type
Centrifugal pump
Coolant tank capacity
6.0 l
Coolant
BTC-15 + BTC-50
Sound level
approx. 67 db(A)
Protection type
IP 23 (suitable for indoor use only)
Dimensions (lxwxh)
490x250x410 mm
690x250x340 mm
Weight
14.9 kg
16.7 kg
Tab. 1
CR1000/CR1250
cooling unit
Ambient temperature
-10°C to +40°C
Relative humidity
Up to 90% at 20°C
Tab. 2
Ambient conditions during operation
Storage in a closed environment, ambient temperature
-10°C to +40°C
Ambient temperature for shipment
-25°C to +55°C
Relative humidity
Up to 90% at 20°C
Tab. 3
Ambient conditions for transport and storage
S.W.
Flow control (water flow switch)
Tab. 4
Abbreviations
Unit of measurement in drawings or diagrams
Millimetres [mm]
Tab. 5
Dimensions