BRS-LC
3 Product description
BAL.0030 • 2019-01-18
EN - 7
3.2 Abbreviations
3.3 Nameplate
The cleaning station
BRS-LC
is labelled with a nameplate on the back as follows:
Internal operating voltage/power supply
24 VDC / 200 mA
Protection type
IP 21
5/2 directional valves
Nominal voltage
24 VDC
Power consumption
4.5 W
Induct. proximity switch NO contact (pnp)
Operating voltage
10 - 30 V DC
Current consumption
approx. 4 mA (at 24 V DC)
Allowed residual ripple
Vss < 10 %
Permanent current
max. 200 mA
Current consumption
approx. 4mA (24V)
Voltage drop
approx. 1.2 V (200 mA)
Tab. 5
Electrical connections
NOTICE
• To guarantee the maximum power and useful life of the torch cleaning station, operate it with clean and oiled air.
Tab. 4 Pneumatic distributor block on page EN-6
Pneumatic motor / nominal speed with oiled air
approx. 800 rpm at 6 bar
Air consumption
approx. 500 l/min
Tab. 6
Compressed-air motor
BRS-LC
BRS-LC
Torch cleaning station
TCP
Tool Center Point
Tab. 7
Abbreviations
Units of measurements in drawings or diagrams
Millimetres [mm]
Tab. 8
Dimensions
Fig. 2
Cleaning station nameplate