BAL.0166 • 2019-01-03
EN - 5
AUT-WIG
3 Product Description
2.6 Emergency information
In case of emergency, immediately interrupt the following supplies:
• Electrical power supply
• Coolant supply
• Compressed air supply
• Gas supply
Further measures can be found in the "Power source" operating instructions or in the
documentation of further peripheral devices.
3 Product Description
3.1 Technical Data
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
• Only qualified personnel are permitted to perform work on the device or system.
Ambient temperature Welding
- 10 °C to + 40 °C
Transport and storage
- 25 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Physical conditions
Type of voltage
DC or AC
DC polarity of the electrodes
Usually negative
Type of use
automatic
Voltage rating
141 V peak value
Max. arc ignition and stabilization voltage
6 kV
Protection type of the machine-side
connections (EN 60 529)
IP2X
Shielding gas (DIN EN ISO 14175)
Argon
Electrode
industry standard tungsten electrodes suitable for
TIG use, preferably low radiation
Tab. 2
General torch data (EN 60 974-7)