EN - 13
ABITIG
®
WH
6 Putting into operation
Charge the entire cooling system as follows when used for the first time and
after every cable assembly change:
1
Disconnect the coolant return hose
from the coolant recirculator
and
hold it over a collecting device.
2
Close the opening at the coolant return hose
and open it again by
repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles into the collecting device.
3
Switch off the coolant recirculator
and reconnect the coolant return
hose
6.7 Connecting the control lead
The control lead is open on the machine side. The customer has to provide the
connection of a suitable plug. If all data are complete, everything will be
delivered ready for connection. Otherwise choose a compatible plug for your
power supply and solder it to the corresponding leads according to the
connection diagram.
1
Coolant return hose
2
Coolant recirculator
Fig. 4
Connecting the coolant
1
2
1
Emergency-off
Sensor
Fig. 5
Connecting the control lead
2
3
1
1
2
WH
BN
GN
BN
WH
GN
BN
WH