EN - 21
ABIPLAS
®
CUT
8 Putting out of operation
8 Putting out of operation
1
Switch off the cutting power source.
2
Close the compressed air feed.
9 Maintenance and cleaning
Scheduled maintenance and cleaning is a prerequisite for a long life and a
trouble-free operation.
WARNING
Blinding of the eyes
The arc produced by welding can damage the eyes.
• Wear protective clothing and eye protection.
NOTE
• The
ABIPLAS
®
CUT
welding torches may only be operated by
qualified personnel.
• As the
ABIPLAS
®
CUT
welding torches are integrated into a welding
system, the operating instructions of the welding components, such as the
robot control system, must be observed during operation.
• Check the actual gas flow at the measuring instruments or by closing and
opening the corresponding gas outlet openings at the torch.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power source.
• Close off the compressed air supply.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.