EN - 17
ABIPLAS
®
CUT 200 W/MT
6 Putting into operation
Bleed the entire cooling system as follows when used for the first time and after
every cable assembly replacement:
1
Disconnect the coolant return hose
from the coolant recirculator
and
hold it over a collecting device.
2
Close the opening on the coolant return hose
and then re-open it by
abruptly releasing it. Repeat this process until the coolant flows into the
collecting device continuously and without air bubbles.
3
Switch off the coolant recirculator
and re-connect the coolant return
hose
6.3.1 Compressed air for plasma and cooling gas
• Precise adjustment of the compressed air pressure and flow/volume are
important for igniting the pilot arc, the quality of cut and the service life of
the torch and wear parts.
Tab. 3 Product-specific torch data (EN 60 974-7) on page EN-8
1
Coolant return hose
2
Coolant recirculator
Fig. 6
Connecting the coolant
1
2