16. GENERAL SAFETY

This installation manual is intended for qualified personnel.
The installation, electrical connections and adjustments must be 
made in compliance with the following European Directives:  
2004/108/EC, 2006/95/EC and subsequent amendments.
Read the instructions carefully before starting the installation.
Incorrect installation can be a source of danger.
The packaging materials (plastic, polystyrene, etc..) should not be
disposed of properly and should not be left within reach of  
children as they are potential sources of danger.
Before starting the installation, check the integrity of the product.
Do not install the product in explosive areas and atmospheres:
presence of flammable gases or fumes are a serious safety hazard.
Before installing the motors, make all structural changes relating 
to construction safety clearances and protection or segregation of 
all areas of crushing, shearing, trapping and general danger.
Verify that the existing structure has the necessary strength and 
stability.
The motor manufacturer is not responsible for the workmanship 
in the construction of frames to be motorized or for any deforma-
tion occurring during use.
The safety devices (photocells, safety edges, emergency stops, 
etc..) must be installed taking into account: applicable laws and 
directives in force, Good Working Methods, installation environ-
ment, the logic of the system and the forces developed by the 
motorized door or gate.
The safety devices must protect any areas of crushing, shearing,
trapping and general danger of the door or gate.
The signs required by law to identify danger areas.
Each installation must clearly show the identification details of the 
motorized door or gate.
Before connecting the power supply, make sure the data plate 
correspond to those of the electricity distribution network.
Install on the power supply, if necessary, a switch / isolating switch 
with a contact opening distance equal to or greater than 3 mm. 
Check that upstream of the electrical system there is a differential 
switch and a suitable circuit breaker.
When prompted, connect the motorized door or gate to an 
effective system of earth terminal in accordance with applicable 
safety standards.
While performing installation, maintenance and repair, interrupt 
the power supply before opening the cover to access the electrical 
parts.
The electronic parts must be done by arranging grounded antista-
tic conductive bracelets.
The motor manufacturer is not liable for any components which 
are incompatible with the safety and efficient operation.
For repairs or replacements of products only original spare parts 
must be used.
The installer must supply all the information relating to the 
automation, manual and emergency operation of the motorized 
door or gate, and operating instructions and deliver it to the user 
of the automation.
Everything that is not EXPRESSLY specified in these instructions is
not permitted.
The access to the electrical compartment must be performed by
qualified personnel only.

MAINTENANCE (EVERY 6 MONTHS)

Remove the power supply 230V or batteries to obscure the solar panel 
if present.
Clean and grease the levers and chains in the mechanism.
Check that the screws that connect the gearmotor to the barrier and 
the screws that connect the spring to the barrier are tight.
Check the tightness of the linkage and that the system works without 
unusual play.
Check the manual release. Check the balance of the spring. Replace 
any worn parts. Check the state of charge of the battery and recharge 
or replace if necessary.
Reconnect the power supply 230V or batteries and the solar panel if 
present.
Check the function of electromechanical limit switches. Check the 
function of obstacle detection. Check the proper functioning of all 
functions of control and safety.

DISMANTLING

When the automation system is disassembled to be reassembled on 
another site you need to:
- Turn off the power and disconnect the batteries and the solar
panel if present
- Unlock the automation and bring the rod in the fully open position so 
that the balancing spring is unloaded and relock the automation.
- Remove the barrier from its anchorage to the ground
- Preparing a new anchor to the ground at the new site (order founda-
tion plate base PLATE/004)
- Replace any damaged or worn parts.

DEMOLITION

Disposal of materials must be carried out in accordance with local 
regulations. In the case of scrapping, the sure to unlock the automa-
tion and bring the rod in the fully open position so that the balancing
spring is unloaded before disassembling the automatism.
Materials must be separated for recycling (electrical components - 
copper - aluminum - plastic - etc ...).
The batteries must be removed safely (12V - 12Ah).
Remove and dispose of them separately as required by law.

The smooth operation is only ensured if the data are respected
in this manual. The Company is not liable for damages caused by not 
respecting the installation standards and the instructions contained in 
this manual. The descriptions and illustrations in this manual are not 
binding. Preserving the essential characteristics of the product, the 
Company reserves the right to make changes at any time deemed 
appropriate to improve the technical, manufacturing and commercial 
product, without being required to update this publication.

Summary of Contents for ELIOX

Page 1: ...is a trademark of AB Tecno srl Via Cicogna 95 40068 S Lazzaro di Savena BO info abtecno com www abexo tech ...

Page 2: ...2 OLMAX n 6 n 5 n 13 n 10 ...

Page 3: ...Batterie asgm Barriere Schlüssel 3419 sb900 solar Platte 004 sb 802 optional sb 803 optional ...

Page 4: ... ...

Page 5: ... ...

Page 6: ... ...

Page 7: ... ...

Page 8: ... ª ª ª ª ª ª ª ª ª ...

Page 9: ... ...

Page 10: ...he box Connect the red cable to the red terminal Connect the black cable to the black terminal Wiring accessories After connecting the reflex photocell to the control unit the polarized mirror must be instal led on the opposite side from the barrier To check that the mirror is positioned correctly use the procedure in par 5 6 Check that in the second line of the control unit display the FT1 input ...

Page 11: ... ª ª ª ª ª ª ª ª ...

Page 12: ...rt 1 command Start 2 command Q1 position motor 1 Q2 position motor 2 18 1 MENU STATUS Press button to change menu and go to the following one Press OK and select the chosen logic Press OK and then press the button of the transmitter you want to program do not program a transmitter on solar automations Press OK and select the time that the gate must remain open with AUTOMATIC or CONDOMINIUM logic P...

Page 13: ... ...

Page 14: ...n For repairs or replacements of products only original spare parts must be used The installer must supply all the information relating to the automation manual and emergency operation of the motorized door or gate and operating instructions and deliver it to the user of the automation Everything that is not EXPRESSLY specified in these instructions is not permitted The access to the electrical co...

Page 15: ...e manufactures can not be held responsible for any damage caused by improper incorrect or unreasonable Avoid operating in the proximity of the hinges and of moving mechanical parts Do not enter the field of action of the motorized barrier while it is moving Not obstruct the motion of the motorized barrier since this may be dangerous Do not allow children to play or stay within range of the motoriz...

Reviews: