Transportation and storage
Note:
Handle the equipment with caution. Subjecting it to rough handling may cause
damage and create a perilous condition or render the warranty void.
The control panel should NOT be exposed to rain, moisture, or snow.
Ensure that the unit is secured before storage and transporting to avoid damaging
impact on the internal components.
During transportation, ensure that the unit is secured to prevent possible sliding and
cause injury to the occupants in the vehicle.
Maintenance
**
For more detailed instructions, visit www.unipdry.com**
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body
• Use a soft, damp cloth to clean the exterior of unit. Do not use any
soap or solvents
Coil Maintenance
Once per year, clean the coils with an approved coil cleaner. The
coil cleaner should be a self-rinsing,
foaming, cleaner, such as
WEB® Coil Cleaner.
Cleaning the Filter
1. Unplug the unit.
2. For PreFilter:
a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).
3. For MERV-10/HEPA/Carbon Filters:
a. Replace as necessary- we
recommend checking the filters
at least 1x/year
Electrical Access
•
• Remove the screw on the
control board cover.
Unscrew the 13 screws on the side panel.
9
10
6. Water Pump working interface display
Compressor protection time not shown:
“Pump working countdown”:
indicates: No matter in which
working state and interface, as long as the pump works, this
interface appears and counts down to 28 seconds.However,
the interface only displays the previous working status and
interface after 3 seconds.For example, after 3 seconds, there
is a drainage icon on the main interface and it
will flash until the drainage is finished.
7.Interface display in case of failure
Machine running time fault display:
Make fault judgment and take corresponding actions after starting
up. Regardless of the state, the fault is executed first and the fault
code is displayed on the interface. If there is a fault in the
sub-menu operation, immediately return to this interface display
fault (including defrosting state). (the fault is judged when the pump
works, and the fault is displayed as usual, but the pump needs to
complete the water pumping this time). Multiple faults can be
displayed at the same time.
Description of fault display:
Humidity sensor fault: when the humidity sensor unit fault or signal can not be transmitted, the fault is
judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button
can operate.
Ambient temperature T
≤
2: When the sensor continuously detects the ambient temperature of inlet air
T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values,
corresponding to the temperature region operation. (recoverable). At this time, the interface cannot
be operated. The pump button can be operated.
Ambient temperature T
≥
45: When the sensor continuously detects the inlet air environment
temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped.
Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface
cannot be operated. The pump button can be operated.
3.1 Air Filter
Make
a
point
of
regularly
checking
the
pleated
fabric
air
filter
fitted
into
the
FireWaving
200
.
The
filter
is
a
standardized
MERV
-
11
filter
,
of
high
efficiency
.
Operating
the
unit
with
an
obstructed
or
dirty
filter
could
lead
to
damage
and
accidents
.
The
heating
elements
will
commonly
shut
off
in
these
situations
.
Yu
need
to
clean
he
filters
or
replace
them
t
regain
the
functionalities
again
.
Usually
,
the
filter
can
be
cleaned
many
times
before
it
requires
replacement
.
You
can
order
your
filters
for
replacement
directly
from
the
factory
,
or
bought
locally
where
possible
.
WARNING
!
DO
NOT
USE
THE
UNIT
WITHOUT
THE
FILTER
OR
EVEN
WITH
A
DEFECTIVE
ONE
.
You
could
clog
up
the
heating
coils
installed
in
the
unit
.
In
that
case
,
you
will
need
to
disassemble
the
whole
unit
for
just
cleaning
them
.
4.SERVICE
WARNING
:
Note
that
servicing
the
FireWaving
200
is
a
risky
venture
.
The
unit
runs
on
high
voltage
power
and
could
easily
cause
death
,
in
case
someone
makes
the
wrong
step
.
Therefore
,
to
keep
safe
and
guarantee
safety
of
those
around
,
and
property
,
you
must
only
use
a
qualified
and
authorized
technician
to
do
the
servicing
.
You
should
never
operate
the
unit
with
the
front
cover
left
open
,
lest
the
heater
burns
as
a
result
of
the
high
voltage
power
.