background image

Transportation and storage

Note: 

Handle the equipment with caution. Subjecting it to rough handling may cause 

damage and create a perilous condition or render the warranty void.

The control panel should NOT be exposed to rain, moisture, or snow.

Ensure that the unit is secured before storage and transporting to avoid damaging 
impact on the internal components.

During transportation, ensure that the unit is secured to prevent possible sliding and 
cause injury to the occupants in the vehicle. 

Maintenance

**

For more detailed instructions, visit www.unipdry.com**

WARNING: Always unplug the unit before doing any maintenance.

Cleaning the Machine Body

• Use a soft, damp cloth to clean the exterior of unit. Do not use any
soap or solvents

Coil Maintenance

Once per year, clean the coils with an approved coil cleaner. The

 

coil cleaner should be a self-rinsing, 

foaming, cleaner, such as

 

WEB® Coil Cleaner.

Cleaning the Filter

1. Unplug the unit.

2. For PreFilter:

a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).

3. For MERV-10/HEPA/Carbon Filters:

a. Replace as necessary- we 
recommend checking the filters
at least 1x/year

Electrical Access

• 

• Remove the screw on the

control board cover.

Unscrew the 13 screws on the side panel.

9

10

6. Water Pump working interface display

 

Compressor protection time not shown:

“Pump working countdown”:

 indicates: No matter in which 

working state and interface, as long as the pump works, this 
interface appears and counts down to 28 seconds.However, 
the interface only displays the previous working status and 
interface after 3 seconds.For example, after 3 seconds, there 
is a drainage icon on the main interface and it 
will flash until the drainage is finished.

7.Interface display in case of failure

Machine running time fault display:

Make fault judgment and take corresponding actions after starting 
up. Regardless of the state, the fault is executed first and the fault 
code is displayed on the interface. If there is a fault in the 
sub-menu operation,  immediately return to this interface display 
fault (including defrosting state). (the fault is judged when the pump 
works, and the fault is displayed as usual, but the pump needs to 
complete the water pumping this time). Multiple faults can be 
displayed at the same time. 

Description of fault display:

     Humidity sensor fault: when the humidity sensor unit fault or signal can not be transmitted, the fault is 
judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button 
can operate.

     Ambient temperature T

2: When the sensor continuously detects the ambient temperature of inlet air 

T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values, 
corresponding to the temperature region operation. (recoverable). At this time, the interface cannot 
be operated. The pump button can be operated.

     Ambient temperature T

45: When the sensor continuously detects the inlet air environment 

temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped.
Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface
cannot be operated. The pump button can be operated.

3.1 Air Filter

Make

 

a

 

point

 

of

 

regularly

 

checking

 

the

 

pleated

 

fabric

 

air

 

filter

 

fitted

 

into

 

the

 

FireWaving

 

200

The

 

filter

 

is

 

a

 

standardized

 

MERV

-

11

 

filter

of

 

high

 

efficiency

Operating

 

the

 

unit

 

with

 

an

 

obstructed

 

or

 

dirty

 

filter

 

could

 

lead

 

to

 

damage

 

and

 

accidents

The

 

heating

 

elements

 

will

 

commonly

 

shut

 

off

 

in

 

these

 

situations

Yu

 

need

 

to

 

clean

 

he

 

filters

 

or

 

replace

 

them

 

t

 

regain

 

the

 

functionalities

 

again

Usually

the

 

filter

 

can

 

be

 

cleaned

 

many

 

times

 

before

 

it

 

requires

 

replacement

You

 

can

 

order

 

your

 

filters

 

for

 

replacement

 

directly

 

from

 

the

 

factory

or

 

bought

 

locally

 

where

 

possible

.

WARNING

DO

 

NOT

 

USE

 

THE

 

UNIT

 

WITHOUT

 

THE

 

FILTER

 

OR

 

EVEN

 

WITH

 

A

 

DEFECTIVE

 

ONE

You

 

could

 

clog

 

up

 

the

 

heating

 

coils

 

installed

 

in

 

the

 

unit

In

 

that

 

case

you

 

will

 

need

 

to

 

disassemble

 

the

 

whole

 

unit

 

for

 

just

 

cleaning

 

them

4.SERVICE

WARNING

Note

 

that

 

servicing

 

the

 

FireWaving

 

200

 

is

 

a

 

risky

 

venture

The

 

unit

 

runs

 

on

 

high

 

voltage

 

power

 

and

 

could

 

easily

 

cause

 

death

in

 

case

 

someone

 

makes

 

the

 

wrong

 

step

Therefore

to

 

keep

 

safe

 

and

 

guarantee

 

safety

 

of

 

those

 

around

and

 

property

you

 

must

 

only

 

use

 

a

 

qualified

 

and

 

authorized

 

technician

 

to

 

do

 

the

 

servicing

.

You

 

should

 

never

 

operate

 

the

 

unit

 

with

 

the

 

front

 

cover

 

left

 

open

lest

 

the

 

heater

 

burns

 

as

 

a

 

result

 

of

 

the

 

high

 

voltage

 

power

.

Summary of Contents for Water Damage Series

Page 1: ...as we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Water Damage Series Add Berlin Tel 44 20 81243974 Email www abestorm com Fire Waving 200 Heater ...

Page 2: ...ot use the hater in wet environments such as bathrooms kitchens and similar locations where there is high humidity and wetness Avoid keeping or stationing the heater where it can slide and fall into water Avoid running the cord under carpets or covering it with any materials Similarly there should be no routing under furniture or any other equipment Only run the cord in spaces that have not traffi...

Page 3: ...ongly and reduce the possibility of impact damage to themselves or even injuring people 2 2 Electrical Requirements You will need a 120VAC power source to operate the FireWaving 200 s blower first heater circuit and the control It is fitted with three more elements that are separately powered with additional receptacles and cords Each of the 120VAC heating parts needs connection to cord and an app...

Page 4: ...ear When the operation is completed the working time of the main interface and the working time of this interface will be reset and started to be instant again After accumulation 9999 clean up and round 3 2 3 3 Coil Temp 000 Used to display the current temperature of the coil When it is below zero the symbol is displayed in front is not required on zero Only applicable to app controlled dehumidifi...

Page 5: ...ompressor protection time not shown Compressor ready IN 03 00 indicates That the interface will be displayed when the compression is in a protected state including power on and shutdown the humidity rises immediately after the arrival of L0 HI and the shutdown resumesimmediately after the emergence of L0 HI Displays the countdown in seconds If the above situation does not occur within 3 minutes it...

Page 6: ...mbient temperature of inlet air T 2 degrees for 600 seconds the fault is judged to be LO and the whole machine is stopped Other values corresponding to the temperature region operation recoverable At this time the interface cannot be operated The pump button can be operated Ambient temperature T 45 When the sensor continuously detects the inlet air environment temperature T 45 degrees for 15 secon...

Page 7: ...air flow into the unit at all There is an additional safety switch fitted to regulate the incoming air temperature to about 140F The switch turns the heating elements off and resets automatically when the temperature reduce to acceptable levels 130F in this case f 5 Accessories and Options 4033895 Duct Kit Compact Heater 8 inlet no flex Duct 4030733 Filter Package 12 PK 9 x 11 3 8 x Mini Pleated M...

Page 8: ...13 14 6 Wiring Diagram 7 Service Parts ...

Page 9: ...replaces any of the Phoenix FireBIRD Compact 2O part the warranty will only apply for the remainder of the period of warranty starting when the item was purchased However any period when the manufacturer is out of service as the customer awaits covered warranty will be added to the original warranty period 15 16 warrantor Berlin Tel 44 20 81243974 VERBAL WARRANTY CLAIMS FireWaving 200 SHALL NOT BE...