ABBRA INSTALLATION GUIDE Version.04 4/12/17 

31 

Federal Communications Commission (FCC) Statements 

FCC PART 15 STATEMENT

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may 
not  cause  harmful  interference,  and  (2)  This  device  must  accept  any  interference  received,  including  interference  that  may 
cause undesired operation. 

WARNING!  Changes  or  modifications  to  this  unit  not  expressly  approved by the party responsible for compliance 
could void the user's authority to operate the equipment

.

 

 

The digital circuits of  this device has been tested and found to comply with the limits for a Class B digital device, pursuant to 
Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in 
residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  and  television  reception.  However,  there  is  no 
guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be 
verified by turning  the  device off and on, the user is encouraged to eliminate the interference by one or more of the following 
measures: 
– Re-orient or re-locate the receiving antenna. 
– Increase the distance between the device and the receiver. 
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. 
– Consult the dealer or an experienced radio/TV technician.

 

 

FCC PART 68 STATEMENT

 

This equipment complies with  Part 68 of the FCC rules.  On the front cover of this equipment is a label that contains, among 
other  information,  the  FCC  registration  number  and  ringer  equivalence  number  (REN)  for  this  equipment.  If  requested,  this 
information must be provided to the telephone company. 

This equipment uses the following jacks: An RJ31X is used to connect  this equipment to the telephone network. The REN is 
used  to  determine  the  quantity  of  devices  which  may be connected  to the telephone line. Excessive  RENs on the telephone 
line  may  result  in  the  devices  not  ringing  in  response  to  an  incoming  call.  In  most,  but  not  all  areas,  the  sum  of  the  RENs 
should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the 
total  RENs,  contact  the  telephone  company  to  determine  the  maximum  REN  for  the  calling  area.  If  this  equipment  causes 
harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may 
be required. If advance notice is  not practical, the telephone company will notify the customer as soon as possible. Also, you 
will  be  advised  of  your  right  to  file  a  complaint  with  the  FCC  if  you  believe  necessary.  The  telephone  company  may  make 
changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, 
the  telephone  company  will  provide  advance  notice  that  will  enable  you  to  make  the  necessary  modifications  in  order  to 
maintain uninterrupted service. 

If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble 
is  causing  harm  to  the  telephone  network,  the  telephone  company  may  request  that  you  remove  the  equipment  from  the 
network until the problem is resolved. 

There  are  no  user  serviceable  components  in  this  product,  and  all  necessary  repairs  must  be  made  by  the  manufacturer. 
Other repair methods may invalidate the FCC registration on this product. 

This  equipment  cannot  be  used on telephone company-provided coin service. Connection to  Party Line Service is  subject  to 
state tariffs. 

When  programming  or  making  test  calls  to  an  emergency  number,  briefly  explain  to  the  dispatcher  the  reason  for  the  call. 
Perform such activities in the off-peak hours; such as early morning or late evening. 

Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be 
able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone 
line in use. To do so, alarm dialing equipment must be connected to a properly installed RJ31X jack that is electrically in 
series with and ahead of all other equipment attached to the same telephone line. If you have any questions concerning 
these instructions, you should consult your telephone company or a qualified installer about installing the RJ31X jack and 
alarm dialing equipment for you.

 

    

 

 

Summary of Contents for Fully Supervised Wireless Alarm Control System

Page 1: ...eliminary Guidance 11 4 4 2 Entry Delays 1 2 11 4 4 3 Exit Delay 11 4 4 4 Bell Time 11 4 4 5 Abort Time 11 4 4 6 Alarm Cancel 11 4 4 7 Quick Arm 12 4 4 8 Bypass 12 4 4 9 Exit Mode 12 4 4 10 Piezo Beeps 12 4 4 11 Trouble Beeps 12 4 4 12 Panic Alarm 12 4 4 13 Swinger Stop 12 4 4 14 Cross Zoning 12 4 4 15 Supervision 12 4 4 16 NOT READY 12 4 4 17 AUX Button 12 4 4 18 Jam Detect 12 4 4 19 Latchkey 12 ...

Page 2: ...to the master user after testing the system Appendices A 1 and A 2 will help you prepare an installation plan Please take time to fill out the forms your job will become much easier and confusion will be prevented Filling out the forms will also help you create a list of detectors and transmitters that must be obtained for the particular application Compatible detectors and transmitters are listed...

Page 3: ...arm in accordance with zone attributes Siren Signals Continuous intrusion 24 hours panic triple pulse pause triple pulse fire Siren bell Timeout Programmable 4 min by default Internal Sounder Output At least 85 dBA at 10 ft 3 m Supervision Programmable time frame for inactivity alert Special Functions Speech and sound control Powerline Carrier Device Control up to fifteen X 10 brand units by vario...

Page 4: ... to Pager PIN No èAlarm Type èZone No 2 5 Physical Properties Operating Temp Range 32 F to 120 F 0 C to 49 C Storage Temp Range 4 F to 140 F 20 C to 60 C Humidity 85 relative humidity 30 C 86 F Size 10 13 16 x 8 x 2 1 8 in 275 x 203 x 55 mm Weight 990g 2 2 pounds without batteries Color Ivory and charcoal gray 3 INSTALLATION 3 1 Unpacking the Equipment Open the cardboard packing box and check whet...

Page 5: ...INSTALLATION GUIDE Version 04 4 12 17 5 Figure 3 1 Backup Battery Installation Open cover 1 Keypad cover 2 Remove screw and open battery compatment Remove screw to release wall mount bracket Connect battery 3 ...

Page 6: ...6 ABBRA INSTALLATION Figure 3 2 Mounting the Control Panel ...

Page 7: ...eries has simple phone X 10 and AC power jacks pre installed No power or phone wiring is required simply plug the AC power cord into the AC power jack the phone cord into the telephone jack and the X 10 cord into the X 10 jack as applicable This schematic is provided for reference and for use in hard wiring sensors to zones 29 and 30 ...

Page 8: ...o 1 3 8 Connecting Abbra to Computer The control panel can be equipped with an optional RS232 module for serial data interchange with a local computer If this module is not supplied a special plastic cap blocks the niche designed to accommodate the module RJ 45 or RJ 31X USA 1 Remove plastic cap Insert the RS 232 adapter into its male connector until a click is heard 2 Figure 3 4 Connecting the Ab...

Page 9: ...ireless siren Before beginning gather all the devices that you intend to enroll and make sure they all have batteries installed Your control panel must recognize the unique identification code ID of each such device in order to supervise them receive their signals and respond accordingly Attention CodeSecure transmitters are mainly used for arming disarming and can not be enrolled to zones For enr...

Page 10: ...nrolling action NEXT OK ENROL WL SIREN NEXT WL siren No 1 or 2 e g 2 SIREN No siren No 2 siren No 2 OK OK OFF TO DELETE Momentarily press the wireless siren self test button until a squawk is heard 1 sec approx TRANSMIT NOW Enrolling a wireless siren siren No 2 for next enrolling action NEXT Deleting a wireless siren siren No 2 A W A Y 2way kp No 2 Deleting a wireless keypad MKP 150 Press MKP 150 ...

Page 11: ...olumns even before you start and proceed to program according to your own list Remember A delay zone is also a perimeter zone by definition Zone types are fully explained in Appendix D For UL installations hard wired zones are not intended to be used as FIRE zones Selectable Zone Names Dining room Downstairs Emergency Fire Front door Garage Garage door Guest room Hall Kitchen Laundry room Lving ro...

Page 12: ...ring which the beeping rate increases Locations No 1 entry delay 1 and 2 entry delay 2 allow you to program the length of these delays Available options for each delay are 00s 15s 30s 45s 60s 3m and 4m In UL installations these delays must be 45 s max 4 4 3 Exit Delay fig 4 4 location 03 An exit delay allows the user to arm the system and leave the protected site via specific routes and doors with...

Page 13: ...urs after having been bypassed if the system remains armed The available options are shut after 1 shut after 2 shut after 3 and no shutdown In UL installations No Shutdown must be selected 4 4 14 Cross Zoning fig 4 4 location 14 Do not use in UL installations Here you determine whether cross zoning will be active or inactive Cross zoning is a method used to counteract false alarms an alarm will no...

Page 14: ...ated The available options are enable and disable 4 4 28 Disarm Option fig 4 4 location 28 Here you determine when it is possible to disarm the system A Any time B During entry delay by using the Abbra keypad or wireless device keyfob C During entry delay byusing a wirelessdevice keyfob only D During entry delay or by using the PowerMax keypad in AWAY mode Options any time on entry all on entry wi...

Page 15: ... entry dly1 30 s entry dly1 45 s entry dly1 60 s entry dly1 3 m entry dly1 4 m abort time 00 s abort time 15 s abort time 30 s abort time 45 s abort time 60 s abort time 2 m abort time 3 m restart exit off by door normal NEXT OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK bell time 3 m NEXT NEXT abort time 4 m NEXT OK NEXT Note The currently saved options are displayed with dark box at t...

Page 16: ...waits 5 seconds F 5 Not applicable in phone numbers To enter a series of digits use the following keys Numeric keypad to enter the number Next Item moves the cursor from left to right Back moves the cursor from right to left Off deletes everything after the cursor to the right 4 5 1 Autotest Time fig 4 5 location 01 Here you determine the time at which the telephone line will be tested and reporte...

Page 17: ...the pager s address The paging company s computer needs this input for routing messages to the specific pager The PIN sequence precedes any digital message that the Abbra sends to the pager to report an event It may include digits pauses and special characters or Call the paging company to find out what the pager s PIN code should consist of Important In this location special characters can be ent...

Page 18: ...stalled or not installed Available options are installed or not installed 4 6 2 1st 2nd 3rd 4th SMS Number Here you define the first second third and fourth SMS phone number including area code 16 digits maximum to which pre selected events types see next paragraph will be reported 4 6 3 Reporting to SMS Phone Number Here you determine the types of events that will be reported to the pre selected ...

Page 19: ... 3 Defining INT STRB Here you determine if the INT output will be used for an internal siren or for a strobe 4 7 4 X 10 GENERAL DEF Not evaluated by UL For X 10 devices you can select the following actions n FLASH ON ALARM you can select no flash or all light flash to control X 10 lighting devices in alarm conditions n TRBL INDICATION you can select don t indicate or indicate for X 10 failure indi...

Page 20: ...T PGM NEXT PGM NEXT Dxx BY ARM AWAY Dxx BY ARM HOME Dxx BY MEMORY OK ONE WAY UNIT PLEASE WAIT test fail test OK NEXT TWO WAY UNIT OK OK OK OK to Enroll enroll OK Enroll FAIL enroll fail HOME Exit X 10 Learn mode OK OK Exit Learn Mode PLEASE WAIT OK to test OFF to Delete if already enrolled Turn X 10 to Learn mode NEXT OK OK pulse time 2s pulse time 30s pulse time 4m pulse time 2m Dxx PULSE TIME PG...

Page 21: ...ee fig 4 3 The recording process is shown below NEXT OK HOUSE IDENTITY 8 RECORD SPEECH see figure 4 1a USER 5 NAME NEXT USER 6 NAME NEXT USER 7 NAME NEXT USER 8 NAME RECORDING ENDED TALK NOW RECORD A MESSAGE e g John s house NEXT RECORD MESSAGE is displayed momentarily The dark square boxes slowly disappear one by one until end of recording time To check the recorded message press the key and list...

Page 22: ...em does not recognize your installer code this indicates you must have programmed a user code that is identical with your installer code If so access the user menu and change the code that is identical with your installer code This will re validate your installer code 4 11 RETRIEVING FACTORY DEFAULTS If you want to reset the Abbra parameters to the factory default parameters you should enter the i...

Page 23: ...roper function of all detectors in the system a comprehensive diagnostic test is required To perform this test refer to figure 4 9 5 3 Keyfob Transmitter Test Initiate transmission from each transmitter enrolled as a keyfob unit according to the list in Table A2 Appendix A Use each transmitter to arm the control panel AWAY and immediately disarm it Upon pressing the keyfob unit s AWAY key the ARM ...

Page 24: ...ttery pack correct insertion and tightened battery compartment lid the TROUBLE indicator should extinguish However the MEMORY message will now blink in the display caused by the tamper alarm you triggered when opening the battery compartment lid Clear it by arming the system and immediately disarming 6 3 Fuse Replacement The Abbra has two internal fuses that have automatic reset Therefore there is...

Page 25: ...Ψ 11 Gas Ψ 12 Flood Ψ 13 Interior Zone Locations Note down the intended location for each detector When programming you may select one of 26 available zone names plus 5 custom zone names that you can add see Figure 4 3 Define Zones Zones 29 30 only are hardwired zones A2 Keyfob Transmitter List Transmitter Data AUX button Assignments No Type Holder Status or Arming instant PGM Control X 10 Unit Co...

Page 26: ...List Tx Transmitter Type Enrolled to Zone Name of holder Assignment 1 2 3 4 5 6 7 8 9 10 APPENDIX B X 10 Unit and PGM Output Assignments Unit Controlled ON ON ON ON ON ON ON by Timer ON by Zone No ON No Appliance by arm HOME by arm AWAY by disarm by Memory by Delay by Keyfob ON Time OFF Time a b c by line fail 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PGM ...

Page 27: ...ood alarm restore FT Fire Detector Clean XR Sensor Battery Restore FJ Fire detector trouble XT Sensor Battery Trouble FR Fire Restore YR System Battery Restore GA Gas alarm YT System Battery Trouble Disconnection GR Gas alarm restore YX Service Required GT Gas trouble 4 2 Event Codes Note Wireless siren reports to central station on zone 31 or 32 GSM reports to central station on zone 33 Alarms Zo...

Page 28: ...you choose to mute them Exit Delay The exit delay begins once the user arms the system It allows him to leave via interior zones and a doorway before arming actually takes effect When the exit delay starts the buzzer beeps slowly and maintains a slow beeping rate until the last 10 seconds during which it beeps rapidly The Abbra has two types of delay zones for which different delay times may be se...

Page 29: ...s and anti tamper protection They therefore trigger an alarm in both armed and disarmed states 24 Hour Zone Silent Upon detection this zone initiates a silent alarm meaning that the sirens do not function Instead the Abbra dials telephone numbers and reports the event to central stations and or to private telephones as programmed 24 Hour Zone Audible Upon detection this zone initiates a siren alar...

Page 30: ...Y and HOME together for 2 sec initiates PANIC alarm Pressing AWAY for 2 sec initiates Latchkey arming DISARM AWAY AUX HOME MCT 234 B MCT 231 201 N A in North America Single button pendant units The MCT 231 Code Secure and the MCT 201 PowerCode can be enrolled to perform functions as shown Both units look alike MCT 231 201 Not UL listed C MCT 134 104 N A in North America 4 button hand held units MC...

Page 31: ...se to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to the line as determined by the total RENs contact the telephone company to determine the maximum REN for the calling area If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary ...