Assembly Instructions / TPL65-A ... TPL77-A, TPL65VA
5 Storage of new turbochargers and spare parts /
© Copyright 2020 ABB. All rights reserved.
HZTL455311P0017_EN
Rev.A
July 2020
5
Storage of new turbochargers and
spare parts
Storage of new turbochargers and spare parts up to 6 months
New turbochargers and spare parts from ABB Turbocharging can be stored in sealed pack-
aging without additional mothballing measures for up to 6 months from the date of delivery
(marked by the VCI label on the package).
V
olatile
C
orrosion
I
nhibitor (VCI)
Only dry rooms in which the relative humidity is between 40…70 % and no condensation can
form are suitable for storage.
Storage of new turbochargers and spare parts for more than 6 months (VCI)
WARNING
Protection of health when handling VCIs
VCI products are not hazardous in the sense of the Hazardous Substances
Ordinance. Nevertheless, the following points are to be observed when
handling VCIs:
u
Ensure good room ventilation.
u
Do not eat, drink or keep food at the workplace while working with VCIs.
u
Wear safety gloves.
u
Clean hands and face after working with VCIs.
u
For further information refer to
Wear safety gloves to protect against chemical hazards.
The following mothballing measures are required every 6 months:
u
Open the package.
u
Remove the VCI corrosion protection emitter from the package and replace it with a new,
identical VCI corrosion protection emitter. New VCI corrosion protection emitters can be
obtained at
.
u
Dispose of the old VCI corrosion protection emitter in an environmentally compatible
manner, professionally and in accordance with local regulations.
u
Seal the package. The better the external seal is designed, the more permanent the pro-
tection.
Page
14
/
17
Summary of Contents for Turbocharger TPL-A Series
Page 2: ......