6  Technical data 

Manufacturer

 

Address 

ABB AB / JOKAB SAFETY 
Varlabergsvägen 11 

SE-434 39 Kungsbacka 

Sweden 

Article number/Ordering data 

Tina 7A: 2TLA020054R0700 

 

Power supply

 

Operating voltage 

24 VDC +15 %, -25 % 

Total current consumption 

47 mA (57 mA with max information output) 
Information output: Max 10 mA 

Current through safety device contacts 

12 mA 

Short circuit current between contacts 

10 mA 

Time delay t (in/out) 

t < 70 µs 

Voltage supply at normal operation (protection OK) 

and 24 VDC supply voltage 

Dynamic input: between 9 and 13 volt (RMS) 
Dynamic output: between 9 and 13 volt (RMS) 
Information output: ~ 23 VDC 

 

General

 

Protection class

 

IP20 

Ambient temperature 

Storage: -30…+70°C 
Operation: -10…+55°C 

Humidity range 

35 to 85 % (with no icing or condensation) 

Housing material 

PVC 

Connectors 

5-pin connection block (power supply, dynamic in/out, info) 
4-pin connection block (safety loop A1-A2, B1-B2) 

Mounting  

DIN-rail 

Size 

62 x 46 x 13 (L x W x H) 

Weight 

~ 35 g 

Colour 

Black 

 

Safety / Harmonized Standards

 

Conformity 

European Machinery Directive 2006/42/EC 

 

EN ISO 12100-1:2003, EN ISO 12100-2:2003, 
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008, 
EN 62061:2005 

IEC/EN 61508-1…7 

SIL3, PFH

d

: 4.50*10

-9

 

EN 62061 

SIL3 

EN ISO 13849-1 

Performance level: Pl e, category 4 

EN 954-1 

Category 4 

Certificates 

TÜV Nord 

Summary of Contents for Tina 7A

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions Tina 7A Adaptor unit ...

Page 2: ...SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attent...

Page 3: ...rview 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troubleshooting 8 5 Operation 9 LED indication 9 Information output signal attributes 9 6 Technical data 10 Dimensions 11 7 EC Declaration of conformity 12 ...

Page 4: ...of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment ...

Page 5: ... visual status information of the safety sensor and the dynamic safety circuit The Tina 7A adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and reduce the risk of electrical interference the unit must be installed within the same physical encapsulation as the safety device The connection cables should be as shor...

Page 6: ...ion channel output shall never be used for the safety purpose s The safety loops are not monitored and must therefore be installed within the same physical enclosure e g electrical cabinet as the safety device to maintain the highest safety level fault exclusion refer to EN ISO 13849 2 2003 Annex D The safety loops shall not be used for purposes other than intended All loading or tampering with lo...

Page 7: ...2TLC172139M0201 rev B 7 www abb com ljokabsafety 2013 03 02 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables ...

Page 8: ... the safety unit is working properly by following these steps Interrupt the dynamic safety circuit before this unit The LED should flash between green and red Interrupt protection The LED should light red The LED should light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of faults Checking and measures to ...

Page 9: ...al is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signal No dynamic signal 24 VDC 0 VDC Info output signal pin 5 High High Low High The delay for switching the information signal output fr...

Page 10: ...t between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP20 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connectors 5 pin connection block power supply dynamic in out info 4 pin connection block safety loop A1 A2 B1 B2 Mounting DIN rail Size 62 x 46 x...

Page 11: ...ljokabsafety 2013 03 02 Dimensions Tina 7A NB All measurements in millimetres The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB branded product with article number beginning with 2TLA ...

Page 12: ...2TLC172139M0201 rev B 12 www abb com jokabsafety 2013 03 02 7 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety ...

Reviews: