11.15.6
AC input cable specifications (Terra Mobile 54HV)
Parameter
Specification
Cross section of the phase conductors
5x35 mm²
Cross section of the PE conductor
35 mm²
Diameter of AC cable, including shielding 22.5 - 50 mm
Suggested single phase wire cross-sec-
tion
35 mm²
11.15.7
Connector types for the AC input cable
Connector type for the AC input cable (Terra Mobile 44HV)
Parameter
Specification
Connector type on the cable
IEC 60309 3P+N+PE 63 A female plug
Connector type for the AC input cable (Terra Mobile 54HV)
Parameter
Specification
Connector type on the cable
IEC 60309 3P+N+PE 125 A female plug
11.16
DC output specifications
11.16.1
DC output specifications (Terra Mobile 44HV)
Parameter
Specification
DC output voltage range
200-920 V
Minimum DC output current
43 A
Connection standard
CCS (IEC 61851-23:2014 , IEC62196-1:
2014, IEC 62196-3: 2014)
DC output power on one EV charge cable Maximum 40 kW
DC output power on two EV charge ca-
bles
Maximum 40 kW
Simultaneous DC on 2 outlets
No. Only subsequent operation of the
outputs available.
Maximum DC output current
125 A
Charger Capacity
Voltage [V]
Current [A]
Power [kW]
150
125
19
200
125
25
300
125
38
400
100
40
500
80
40
600
67
40
700
57
40
Technical data
60
9AKK108467A6997-EN | 003
Summary of Contents for Terra Mobile 44HV
Page 66: ......