12.19.5
Interlock and DC guard cables
Parameter
Specification
Number of cores
2 x 2 twisted pair (4 core)
Diameter (inside)
1.3 to 2.1 mm² (16 to 14 AWG)
Diameter (outside)
10 to 17 mm (0.39 to 0.67 in)
Shielding
Tinned copper braid
Possible configuration: shielded 4 core
cable 2 x 2 pairs twisted or two separate
shielded dual core cables
Conductor
Fine strand copper wire
Insulation
PVC or other material that is serviceable
for outdoor use and UV-protected
Test voltage
1.5 kV
Strip length
11 mm (0.43 in)
12.19.6
CAN cables
Table 2: CAN cables between power cabinets
Parameter
Specification
Number of cores
1 x 2, twisted and shielded pair
Diameter
0.5 to 0.75 mm² (20 to 18 AWG)
Shielding
Tinned copper braid
Conductor
Fine strand copper wire
Nominal voltage
600/1000 V AC
Insulation
PVC or other material that are serviceble
for outdoor use and are UV-protected
Minimum test
1.5 kV
Strip length
11 mm (0.43 in)
Table 3: Optical CAN cables between the power cabinet and the charge post
Parameter
Specification
Number of cores
2 fibre cores for installation
2 fibre cores as spare parts
Type
OM3 (multimode) prefabricated
Connector
B-FOC (ST
®
)
Diameter
13 to 21 mm (0.51 to 0.83 in)
Wave length
850 nm
Material
PCF or fiberglass
Loop bend radius
Minimum 64 mm (2.5 in)
Strip length
11 mm (0.43 in)
Technical data
9AKK107992A6488-EN | 004