Parameter
Specification
Example of
power out-
put for Ter-
ra 360-12PM
Ambient temperature
Power Out-
put (see
normal duty
rating)
De-rating
Peak dura-
tion
[°C]
[°F]
[%]
[%]
[min]
[kW]
- 35 … + 20
-31 … + 68
100
-
> 30
360 (peak)
+ 21 … + 25
+ 69 …+ 77
100
-
15
360 (peak)
+ 26 … + 30 + 78 …+ 86
100
-
10
360 (peak)
+ 31 … + 35
+ 87 …+ 96
100
-
6,5
360 (peak)
+ 36 … + 40 + 96 …+ 104 100
-
3,5
360 (peak)
+ 41 … + 45 + 105 …+ 113 92
8
-
331 kW
+ 46 … + 50 + 114 …+ 122 83
17
-
300 kW
+ 51 … + 55
+ 123 …+ 131 75
25
-
270 kW
The below table shows the steady state rating of the EVSE.
Parameter
Specification
Example of
power out-
put for Ter-
ra 360-12PM
Ambient temperature
Power Out-
put (see
normal duty
rating)
De-rating
[°C]
[°F]
[%]
[%]
[kW]
- 35 … + 20
- 31 … + 68
100
360
+ 21 … + 25
+ 69 …+ 77
99
1
356
+ 26 … + 30
+ 68 …+ 86
97
3
350
+ 31 … + 35
+ 87 …+ 96
96
4
346
+ 36 … + 40
+ 96 …+ 104
94
6
338
+ 41 … + 45
+ 105 …+ 113
92
8
331
+ 46 … + 50
+ 114 …+ 122
83
17
300
+ 51 … + 55
+ 123 …+ 131
75
25
270
The output power of the EVSE can be limited by the temperature of the charge
connector. This limitation can be caused by the connector model and rating, the EV
socket rating and the ambient conditions.
10.13.3
EVSE rating in heavy duty operation
Heavy duty operation applies for use in public applications with heavy traffic or
commercial/fleet applications.
Technical data
9AKK108467A6398-EN | 002