background image

Conductor

Average compressions per charge

BAT-MK 

500 kcmil

155

750 kcmil

145

Advance trigger

Release button

Ram

Die Half

Slide in

Die Release Pin

Push

Die Release

Knob

C-Head

Die half

Pull

Slide in

ON

OFF

Compression cycles

This guide indicates the number of compression cycles that the 
TBM12PCR-LI can be expected to perform when the battery is 
fully charged. These figures are approximate and will vary 
according to the charging and other operating conditions, such 
as temperature, humidity, and battery condition.

Switch operation

1. The ram advances when the Trigger is depressed and stops 

when the Trigger is released.

2. To retract the ram, depress the Release button. The ram 

continues to retract while the Release button is depressed. If 
the auto-retract feature is activated, the ram will automatically 
retract after the crimp is completed. See “Compression 
operation” section, page 4 for instructions on enabling and 
disabling the auto-retract function.

Compression operation

1. Select the appropriate size dies for the connector.
2. Insert one die half into the C-head by sliding it in while pulling 

the Die Release Knob.

3. Press the trigger (Switch Operation, page 4) to advance the 

Ram until the Die Release Pin is accessible. Insert the other 
half of the die into the Ram while pressing the Die Release Pin.

4. Press the trigger and advance the Ram so the connector is 

held lightly between the dies. Do not deform the connector.

5. Insert the conductor into the connector.
6. Press the trigger until the compression is complete. A series 

of clicks will be heard followed by a release in the pressure 
when compression is complete. The LED indicator will display 
green followed by an audible beep when a complete 
compression is made. In an incomplete compression cycle due 
to early release of the trigger or low battery, the LED indicator 
will flash red followed by a series of multiple audible beeps. 
Check gauge on battery for remaining charge. 

7. Press the release button (“Switch operation” section, page 4) 

to retract the ram. The ram continues to retract while the 
release button is pressed. The ram stops when it is fully 
retracted.

8. Remove the compressed connector from the tool.

Auto retract

The auto retract feature can be toggled on or off depending on 
user preference or specific job requirement. To turn auto 
retraction off, remove rubber grommet and use a flat blade 
screwdriver to rotate the indicator 90 degrees to either position 
as shown below:

4 of 6 - English

Summary of Contents for T&B Tools TBM12PCR-LI

Page 1: ...ons should be performed by a qualified electrician in accordance with national and local electrical codes WARNING Risk of shock disconnect power before installation Never attempt to make a compression on a HOT Line Never assume the power is OFF Determine beforehand if any electrical hazards could exist when making a connection to line or wire Tools are NOT insulated for use on or near conductors U...

Page 2: ...nnecting charger Protect cord from being stepped on tripped over or otherwise subjected to damage or stress Do not disassemble charger or battery pack contact Tool Service Center at 1 800 284 TOOL 8665 when service or repair is required Do not store the tool and battery pack in damp or wet locations or where the temperature may reach or exceed 50 C 122 F such as a metal tool shed or a car in the s...

Page 3: ...y to remain in charger until cool before charging can initiate NOTE Do not place any foreign objects in the Charger 3 Full charge 100 achieved in approximately 45 minutes LED lamp lights green and melody or beep will indicate completion 4 When the battery will no longer charge or hold a charge the LED Lamp blinks alternately from green to red IMPOSSIBLE TO CHARGE 5 When the charger is out of order...

Page 4: ... the trigger Switch Operation page 4 to advance the Ram until the Die Release Pin is accessible Insert the other half of the die into the Ram while pressing the Die Release Pin 4 Press the trigger and advance the Ram so the connector is held lightly between the dies Do not deform the connector 5 Insert the conductor into the connector 6 Press the trigger until the compression is complete A series ...

Page 5: ...1 13 1 No Description Code Qty 22 3 x 10 Drive Pin AW 32 12 1 23 Hanging Strap 558 07A 3 24 M4 x 10 Screw ROB 159 10 25 Switch Unit 24 MKREC PCB 1 26 Power Unit 751 15 1 27 Pump Piston 751 16 4 28 Spring 699 LI200 04 4 29 Cylinder Insert LI200 05 4 30 P 5 Back Up Ring E L LI200 06 4 31 P 5 O ring U565 LI200 07 4 32 M5 X 5 Screw F P 510A 05 2 33 Bush R14A 19 1 34 5 32 Ball 22 21 8 35 Plug 751 17 4 ...

Page 6: ...l Operating instructions TA04694 D tnb abb com US Latin America tnb ca abb com Canada abb com Warranty www public tnb com warranty ta04790 tb2 pdf Registration tnb abb com toolregistration We reserve the right to make technical changes or modify the contents of this docu ment without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibi...

Page 7: ...lectricité nationaux et locaux AVERTISSEMENT Risque de décharge électrique mettre hors tension avant de procéder à l installation Ne tentez jamais de comprimer un câble d une ligne sous tension Ne présumez jamais que le courant est coupé Déterminez à l avance si des risques électriques peuvent exister lors de la connexion à une ligne ou à un câble Les outils ne sont PAS isolés afin de pouvoir être...

Page 8: ...et le cordon électriques ne tirez pas sur le cordon lorsque vous débranchez le chargeur Protégez le cordon pour qu il ne soit pas piétiné endommagé ou soumis à d autres contraintes et pour qu on ne trébuche pas dessus Ne démontez pas le chargeur ou le bloc pile Communiquez avec le Service de réparation d outils au 1 800 284 TOOL 8665 si un entretien ou une réparation est nécessaire Ne rangez pas l...

Page 9: ...ur jusqu à ce qu il soit refroidi avant de commencer la charge REMARQUE Ne placez aucun objet étranger dans le chargeur 3 La charge complète 100 est atteinte en 45 minutes environ Le voyant à DEL s allume en vert et une mélodie ou un signal sonore indique la fin de l opération 4 Lorsque le bloc pile ne peut plus être rechargé ou maintenir une charge le voyant à DEL clignote en alternant du vert au...

Page 10: ...vancer le vérin jusqu à ce que la goupille de dégagement de la matrice soit accessible Insérez l autre moitié de la matrice du côté du vérin tout en appuyant sur la goupille de dégagement de la matrice 4 Appuyez sur la gâchette et faites avancer le vérin de manière à ce que le connecteur soit maintenu légèrement entre les matrices Ne déformez pas le connecteur 5 Insérez le conducteur dans le conne...

Page 11: ...n 7ND 03 1 19 Goupille parallèle 4x18h7 ROB 102 1 20 Goupille parallèle M4x35 7ND 05 1 21 Goupille d interrupteur marche arrêt 751 13 1 No Description Code Qté 22 Goupille d entraînement 3x10 AW 32 12 1 23 Attache pour sangle 558 07A 3 24 Vis M4x10 ROB 159 10 25 Circuit d interruption 24 MKREC PCB 1 26 Unité d alimentation 751 15 1 27 Piston de pompe 751 16 4 28 Ressort 699 LI200 04 4 29 Cylindre ...

Page 12: ...d utilisation TA04694 D tnb abb com États Unis et Amérique latine tnb ca abb com Canada abb com Garantie www tnb ca fr catalogues pdf connexions et mise a la terre outils matrices et trousses installation introduction garantie et points de service pdf Inscription tnb abb com toolregistration ABB se réserve le droit d apporter des changements techniques à ce document ou d en modifier le contenu san...