2TLC010073M0201 Rev.G
33
CH1
Mode
CH2
Status
Action
green
flash green
off
CH1 accepted and
CH2 unaccepted.
A timer function
is counting down
while the safety
relay remains
activated.
off
blue
off
No channels
accepted
Check CH1 and
CH2
off
blue
green
CH1 unaccepted,
CH2 accepted
Check CH1
green
blue
off
CH1 accepted,
CH2 unaccepted
Check CH2
green
blue
green
CH1 and CH2
accepted, the
safety relay wait
for reset
Check reset
settings, wiring
and reset circuit
green
blue
fast flash green
Two-channels
error: CH2 has
been unaccepted
and then
accepted again
while CH1
remained
accepted
Check
installation.
Restore by
opening and
closing both CH:s
at the same time
fast flash green
blue
green
Two-channels
error: CH1 has
been unaccepted
and then
accepted again
while CH2
remained
accepted
Check
installation.
Restore by
opening and
closing both CH:s
at the same time
fast flash green
blue
fast flash green
Reading error on
R1 and R2
Check
installation.
Restore by
opening and
closing both CH:s
at the same time
off
flash blue
off
CH1 and CH2
unaccepted, a
timer function is
counting down
while remaining
inactivated
off
flash blue
green
CH1 unaccepted
and CH2
accepted, a timer
function is
counting down
while remaining
inactivated