Section 3
1MRK 511 371-UEN
IEC 60870-5-103
20
Communication Protocol Manual, IEC 60870-5-103
Distributed busbar protection REB500
Table 24
TYPE IDENTIFICATION: Generic data
0
0
0
0
1
0
1
0
T
ype
I
dentification
10
DATA UNIT
1
0
0
0
0
0
0
1
V
ariable
S
tructure
Q
ualifier
SQ=1, SQ_No.= 1
IDENTIFIER
Spontaneous <1>
C
ause
O
f
T
ransmission
COT
REB500 CU/BU No.
C
ommon
A
ddress of
A
SDU <0 .. 60>
GEN <254>
Fun
ction type
FUN
INFORMATION
Read value of single entry <244>
Inf
ormation number
INF
OBJECT
<0>
Return information identifier RII
{
1, 0, 0
}
Number
of
generic data
sets NGD
{
NO, COUNT, CONT
}
43 H
Generic
identification
number
Group
<41H .. 45H>
01 H
Entry
<1 .. 255>
Current value <1>
Kind
of
description
KOD
DATA STRUCTURE
<23>
DATA TYPE
14
DATA SIZE
GDD
1,0
NUMBER
,
CONT
<9> DOUBLE-POINT I
NFORMATION
DATA TYPE
1
DATA SIZE
GDD 1
1,0
NUMBER
,
CONT
0
0
0
0
0
0
<0 .. 3>
GID 1
<14>
BINARY TIME
DATA TYPE
7
DATA SIZE
GDD 2
1,0
NUMBER
,
CONT
Time stamp (CP56Time2a)
GID 2
3.5.4
Entries for double-point indications
Table 25
Directory entry for GIN 0x4600 (header)
COD
Data type
Length
Num
ber
Value / Significance
<10> Description
<1>
OS
8
ASCII
24
1
"Double-point Indications”
<1>Current value
<3> UI
1
1
Number of DPI defined in this group.
Table 26
Directory entry for GIN 0x4600 (header)
COD
Data type
Length
Num
ber
Value / Significance
<10> Description
<1> os8ascii
20
1
Event text defined by user
<1> Current value
<23> data
structure
14
1
(Includes the following two definitions)
<9> Double
Point
INFORMATIO
N WITH
TRANSIENT
AND ERROR
1
1
TRANSIENT (0) /
OFF (1) / ON (2) /
ERROR (3)
<14> binary
time
7
1
Time stamp (CP56Time2a)