Distributed busbar protection REB500
1MRK 505 352-BEN
Product version: 8.2
Issued: 2016-03-01
Revision: -
28
ABB
Interfaces:
X0
X1000 (not used)
Connection a detachedHMI
(LHMI will be switch off if
X0 is used.))
X1
X1001
LAN0A
100BaseFx/LC
Connection to REB500
Station bus connection
process-bus
IEC 61850-8-1
(via Ethernet switch)
PRP Line A
X8 (not used)
X1002
01
02
03
04
05
06
07
08
09
10
11
12
13
14
LAN0B
100BaseFx/LC
Station bus connection
IEC 61850-8-1
PRP Line B
X1005
LAN1
100BaseFx/LC
Connection to REB500
process-bus
(via Ethernet switch)
X1008
Synchronization input
RS485_GNDC
IRIG-B
RS485_RX TERM
01
02
03
RS485_RX -
RS
RS
04
05
06
RS485_TX TERM
RS485_TX -
RS485_GND
07
08
09
RS485_SI G GND
IRIG-B - / PPS -
IRIG-B + / PPS +
10
11
12
IRIG-B_GNDC
IRIG-B_GND
13
14
RS485_SIG GND
not used
not used
not used
not used
not used
X9 (not used)
IRIG-B - / PPS -
IRIG-B_GNDC
not used
not used
not used
not used
not used
IRIG-B + / PPS -
IRIIG-B_GND
X1009
IEC 60870-5-103
X1010
IRIG-B / PPS-In
not used
Power supply:
X450
X415 (Option)
Main power supply
Redundant power supply
110-250VDC and 100-240VAC
à
Power supply version A
48-125VDC
à
Power supply version B