![ABB Power2 850-M46 Operation Manual Download Page 99](http://html.mh-extra.com/html/abb/power2-850-m46/power2-850-m46_operation-manual_2838038099.webp)
Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4 Disassembly and assembly / 4.5 Axial clearance A prior to disas-
sembly
© Copyright 2019 ABB. All rights reserved.
HZTL4062_EN
Revision A
March 2019
4.5
Axial clearance A prior to disassembly
CAUTION
Clearances outside the tolerance
Serious damage to engines or property can be caused by clearances outside
the tolerance and excessively worn parts.
u
Have the components assessed and, if necessary, replaced by an ABB Tur-
bocharging Service Station.
Fig. 6: Measuring axial clearance A
The axial clearance (A) must be measured prior to removal and after installation of the cart-
ridge group.
u
Measure and note axial clearance (A).
Axial clearance A
[mm]
0.32 ... 0.53
Table 6: Axial clearance A
Page
13
/
43