![ABB Power2 850-M46 Operation Manual Download Page 121](http://html.mh-extra.com/html/abb/power2-850-m46/power2-850-m46_operation-manual_2838038121.webp)
Operation Manual / Power2 850-M / 4.1 Low-pressure stage
5 Taking out of operation at short notice / 5.1 Possible emergency re-
pairs
© Copyright 2019 ABB. All rights reserved.
HZTL4062_EN
Revision A
March 2019
5.1.1
Manufacturing the cover plate
The cover plate and the other parts that are required are not part of the scope of delivery of
ABB Turbo Systems and must be manufactured by the operator on the basis of the drawing
(see Fig. 32: Cover plate / gasket, sleeves and screws
Parts required
¡
1 Cover plate (01) (recommended material: 1.4541 / 1.4571)
¡
1 Gasket (02) (temperature resistant up to 550 °C)
¡
8 additional screws (03) to the screws (42087) from the scope of delivery
¡
15 sleeves (04)
Fig. 32: Cover plate / gasket, sleeves and screws
Cover plate (gasket), sleeves and screws, dimensions [mm]
Ø1
Ø2
Ø3
Ø4
Ø5
B1
B2
L1
M1
655
600
14
14
20
10
32
60
M12
Table 18: Cover plate / gasket
Page
35
/
43