![ABB Power2 650-M46 Operation Manual Download Page 148](http://html.mh-extra.com/html/abb/power2-650-m46/power2-650-m46_operation-manual_2838027148.webp)
Operation Manual / Power2 650-M / 4.2 High-pressure stage
4 Disassembly and assembly / 4.4 Removing the cartridge group
© Copyright 2019 ABB. All rights reserved.
HZTL4066_EN
Revision A
March 2019
WARNING
Looping the lifting gear around the cartridge group
The looped lifting gear can slip off and lead to serious injuries to persons or
even to fatal accidents.
u
Make sure the surface for the loop on the cartridge group is free from oil.
Wear safety gloves to protect against mechanical hazards.
Wear safety helmet.
Fig. 13: Removing the cartridge group
1. Treat threads of studs (51006) with penetrating oil and leave to take effect.
2. Loosen nuts (51007) and remove Verbus Ripp® washers (51003) together with fastening
strips (51002).
3. Attach swivel lifting eyes (01) to the cartridge group (10900)
4. Secure lifting gear to swivel lifting eye and loop around the cartridge group (10900) (see
illustration above).
5. Remove the cartridge group and turn it 90°.
6. Place cartridge group with fitted expansion sleeves (42190) on service support (90012).
7. Hand-tighten the cartridge group with the threaded rod (42191) and the clamping nut
(42201) on the service support (90012).
8. Remove metal C-ring (51105).
u
Measure axial clearance A and radial clearance B
(see Table 12: Permissible clearances A
Page
20
/
39