38 |
P a g e
OVR-15, 27 & 38 LV cabinet Instruction Manual
Sr.
No.
Protection
IEC61850
Identification
Setting range
available in
RER615
For OVR-15 Recloser
600/1A CT & 15.5kV System Voltage
For OVR-27 Recloser
600/1A CT & 27kV System Voltage
For OVR-38 Recloser
600/1A CT & 38kV System Voltage
Setting Range to be
used
(in Nominal Values)
Setting Range to be
used
(in Absolute Values)
Setting Range to be
used
(in Nominal Values)
Setting Range to be
used
(in Absolute Values)
Setting Range to be
used
(in Nominal Values)
Setting Range to be
used
(in Absolute Values)
2 = Go
2 = Go
2 = Go
2 = Go
2 = Go
2 = Go
2 = Go
3 = Bo
3 = Bo
3 = Bo
3 = Bo
3 = Bo
3 = Bo
3 = Bo
4 = Yo, Go
4 = Yo, Go
4 = Yo, Go
4 = Yo, Go
4 = Yo, Go
4 = Yo, Go
4 = Yo, Go
5 = Yo, Bo
5 = Yo, Bo
5 = Yo, Bo
5 = Yo, Bo
5 = Yo, Bo
5 = Yo, Bo
5 = Yo, Bo
6 = Go, Bo
6 = Go, Bo
6 = Go, Bo
6 = Go, Bo
6 = Go, Bo
6 = Go, Bo
6 = Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
7 = Yo, Go, Bo
Operate delay time
EFPADM
60...200000 ms
60...200000 ms
60...200000 ms
60...200000 ms
60...200000 ms
60...200000 ms
60...200000 ms
Circle radius
EFPADM
0.05...500.00 mS
0.05...500.00 mS
0.05...500.00 mS
0.05...500.00 mS
0.05...500.00 mS
0.05...500.00 mS
0.05...500.00 mS
Circle conductance
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Circle susceptance
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Conductance forward
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Conductance reverse
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Conductance tilt Ang
EFPADM
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
Susceptance forward
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Susceptance reverse
EFPADM
-500.00...500.00
mS
-500.00...500.00 mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
-500.00...500.00
mS
Susceptance tilt Ang
EFPADM
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
-30...30°
7
Optional Wattmetric based earth-fault protection (WPWDE) main settings
Directional mode
WPWDE
2 = Forward
2 = Forward
2 = Forward
2 = Forward
2 = Forward
2 = Forward
2 = Forward
3 = Reverse
3 = Reverse
3 = Reverse
3 = Reverse
3 = Reverse
3 = Reverse
3 = Reverse
Current start value
WPWDE
0.010...5.000 × In
0.010...5.000 × In
6-3000A
0.010...5.000 × In
6-3000A
0.010...5.000 × In
6-3000A
Voltage start value
WPWDE
0.010...1.000 × Un 0.010...1.000 × Un
6-600A
0.010...1.000 × Un 6-600A
0.010...1.000 × Un 6-600A
Power start value
WPWDE
0.003...1.000 × Pn 0.003...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
0.003...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
0.003...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
Reference power
WPWDE
0.050...1.000 × Pn 0.050...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
0.050...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
0.050...1.000 × Pn
Internally
calculated based
on
Un ( Max 38kV) ,
In (max 600A)
Characteristic angle
WPWDE
-179...180°
-179...180°
-179...180°
-179...180°
-179...180°
-179...180°
-179...180°