![ABB Orion 3 Base Original Instructions Manual Download Page 37](http://html.mh-extra.com/html/abb/orion-3-base/orion-3-base_original-instructions-manual_5140037.webp)
2TLC
172289M0201
Rev C
37
www.abb.com/jokabsafety
2018-04-17
11 Technical data
Manufacturer
Address
ABB JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Electrical Data
Power supply:
+24 VDC
20%
Consumption, Active unit:
6.5 W max (without load)
Outputs
2 PNP
Short-circuit protection:
Output current:
Output voltage
– ON:
Output voltage
– OFF:
Capacitive load
1.4 A at 55°C
0.5 A max / output
Power supply value less 1 V (min.)
0.2 V max.
2.2 µF at +24 VDC
Response time:
From 11 to 24 ms. See paragraph 12
Electrical protection:
Class III - use SELV/PELV
Connections:
M12 - 8 poles male connector
Cable length (for power supply):
70 m max.
Pollution degree:
2
Optical Data
Light source:
Infrared LED (950 nm)
Resolution:
See paragraph 12
Protected height:
See paragraph 12
Operating distance:
From 0.5 to 6.5 m or 8 m. See paragraph 12
Ambient light rejection:
According to IEC 61496-2:2013
Mechanical and environmental data
Operating temperature:
0…55°C
Storage temperature:
-
25…+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (no condensation)
Protection class:
IP65 (EN 60529:2000)
Vibrations:
Width 0.35 mm, F
requency,10…55 Hz
20 sweeps for each axis, 1 octave/min
(EN 60068-2-6:2008)
Shock resistance:
16 ms (10 G) 10
3
shocks per axis
(EN 60068-2-29:2008)
Housing material:
Painted aluminium (yellow RAL 1003)
Caps material:
PBT Valox 508
Front glass material:
PMMA