ABB MTQ22-FBP.0 Manual Download Page 17

— 

12   The configuration tool makes it possible to set the parameters in an easy way. Several MTQ22-FBP.0 devices can be created in the device tree (left). 

 

The final configuration can be saved to the disk and downloaded into the devices using a standard USB cable.

Parameters

Master Configuration and Supervision

The MTQ22-FBP.0 supports up to four parallel connections to Modbus TCP clients (i.e. PLCs). It is possible to monitor these 
clients for activity and signal a communication fault to the connected FBP devices after an adjustable timeout time.
For security reasons, the access to the MTQ22-FBP.0 can be limited to clients having IP addresses within a user defined 

range. Single addresses or address ranges can be defined.

Network Settings

Before any Ethernet communication takes place, the MTQ22-FBP.0 must have an IP address. It is possible to provide a static 
address or obtain the address via DHCP or the BootP protocol. 

 

In the case of a static IP address, the netmask and the gateway address must also be set manually.

Device Settings

Up to four FBP devices can be connected to the MTQ22-FBP.0. For each port, the connected device type (or NONE) must be 
specified. The MTQ22-FBP.0 then monitors the presence of the configured FBP device. 

Position Supervision

The MTQ22-FBP.0 detects accidental permutation of devices connected to it. Therefore, a specific address (1...254) has to be 
set per port which must match the address (1...254) set in the connected device. The MTQ22-FBP.0 offers status registers to 
read the actual FBP device supervision status via Modbus TCP. 

 

See the Address Map section for details.

Parameter Overview 

Before using the MTQ22-FBP.0 device, the following parameters must be set:

Parameter name

Default settings

DHCP / BOOTP

Manual

IP Address

192.168.171.254

Subnet Mask

255.255.255.0

Standard Gateway

192.168.171.1

Number of Modbus TCP masters under supervision

1

Allowed number of supervised connections missing

0

Allowed Modbus TCP IP Address for master 1 ... 4

0.0.0.0  ... 255.255.255.255 for master 1
0.0.0.0  ... 0.0.0.0 for master 2-4

Timeout for master 1 ... 4

10s

Device port 1 ... 4 used

UMC100

Device address for device 1 ... 4

1,2,3,4

17

U N I V ER S A L  M OTO R  CO N T R O L L ER  U M C 10 0. 3  | 

MTQ2 2- FB P.0  MODBUS  TCP  M A N UA L

Summary of Contents for MTQ22-FBP.0

Page 1: ... MANUAL MTQ22 FBP 0 Modbus TCP communication module Universal Motor Controller UMC100 3 ...

Page 2: ...ndancy protocol MRC Media redundancy client MRM Media redundancy manager TCP IP Transmission Control Protocol Internet Protocol UDP User Datagram Protocol Client Server The Modbus TCP messaging service provides a Client Server communication between devices connected on an Ethernet TCP IP network The device initiating the communication e g a PLC is called the client The device answering the request...

Page 3: ... 9 Installation 11 Ethernet communication 16 Configuration 18 Modbus TCP register map 29 Diagnosis behavior in case of an error 31 Technical data 33 Ordering data 3 UNIVERSAL MOTOR CONTROLLER UMC100 3 MTQ22 FBP 0 MODBUS TCP MANUAL Table of contents ...

Page 4: ... changes configuration file changes third party software updates or patches hardware change out etc to ensure that the security measures that you have implemented have not been compromised and system functionality in your environment is as expected For more information or contact details regarding ABB cyber security go to http www abb com cybersecurity Deployment guideline This device must be conn...

Page 5: ... on the network by routers firewall and similar products Network monitor If required add products which can monitor the network access and traffic Network separation From a cyber security point and the protection of the industry factory system it is advisable to separate the remote con nection gateway from the factory control connected gateways It is highly recommended to contact any cyber securit...

Page 6: ...in two port switch allows the flexible usage in bus star or ring network topologies Up to four masters can concurrently access the connected devices The master connections can be supervised Access via Modbus TCP can be restricted to a limited set of IP addresses The Media Redundancy Protocol MRP is implemented client MRP is standardized in IEC EN 62439 2 and offers redun dancy in case of a single ...

Page 7: ...Switch Switch FBP Interface 01 Different topologies that can be realized with the MTQ22 FBP 0 Ethernet Adapter For the ring structure a special switch must be used See chapter Communication for more information Modbus TCP Modbus TCP is a variant of the Modbus family of simple vendor neutral communication protocols intended for supervision and control of automation equipment Specifically it covers ...

Page 8: ...must be supplied with 24VDC via X6 24V DC 0V Port 1 Port 2 Port 3 RDY TCP Link Data Link Data MTQ22 Port 4 X1 X2 X3 X4 X5 X6 E1 E2 FBP Device Interface Ports Status LEDs FBP Device Interface Ports Power Supply Terminals Micro USB Configuration Port Type B Ethernet Interfaces 02 Top view of the MTQ22 FBP 0 Four FBP devices can be connected to the MTQ22 via the ports X1 to X4 The standard Micro USB ...

Page 9: ...hield of connector X6 Power Supply connection The MTQ22 FBP 0 has to be supplied with 24 V DC on the terminals X6 Using the shield connection is optional FBP Device connection FBP devices e g UMC100 can be connected point to point using the ready made cable CDP17 This option is recommended in non withdraw able installations e g using a mounting plate for the installation In case the FBP device is ...

Page 10: ...technology Connecting the MTQ22 FBP 0 ports 1 to 4 connectors X1 to X4 to the UMC mounted inside a drawer standard mounting rail 05 Connecting the MTQ22 FBP 0 ports 1 to 4 connectors X1 to X4 to the UMC 24V DC 0V Port 1 Port 2 Port 3 RDY TCP Link Data Link Data MTQ22 Port 4 X1 X2 X3 X4 X5 X6 E1 E2 X6 X7 X8 X9 X5 T1 T2 Ca Cb DO Relay C C 0 1 2 Run DI 24V DO Power 0V 24V 0 5 3 Trip Rdy X6 X7 X8 X9 X...

Page 11: ...ch is typically a managed network switch and MRP clients which are typically automation devices like the MTQ22 FBP 0 The MRP master sends out test telegrams cyclically to check the health status of the network If everything is in order it blocks telegrams on one side of its internal switch to avoid loops left side of the next figure If a fault is detected somewhere in the network the MRP master re...

Page 12: ... in the cable compartment where the switch and other central equipment are installed The Ethernet cable is not connected to the UMC mounted inside the drawer But the robust and well known FBP interface goes to the UMC in the drawer Therefore no special measures are required in the event that one or more drawers are withdrawn A removed drawer cannot disturb the Ethernet communication in any way Twi...

Page 13: ... screenshots are taken from the RS20 configuration tool Follow the setup instructions of the switch manual Open the Redundancy page and select the marked options shown in the figure below To get help press the Help button 08 The page Ring Redundancy makes it possible to enable the MRP redundancy protocol and to define the ports that are the start and end of the ring 13 UNIVERSAL MOTOR CONTROLLER U...

Page 14: ...t the same time Different Modbus TCP clients can control FBP devices connected to the same MTQ22 FBP 0 E g Modbus TCP client A controls the UMC100 connected to port 1 and client B controls the FBP devices connected to port 2 4 Monitoring of all devices from the clients is always possible Switch MTQ22 UMC UMC UMC UMC MTQ22 UMC UMC UMC UMC PLC MCC Panel PC I 23 5 A Motor On Fault Twisted Pair Ethene...

Page 15: ...ws a system with a central SCADA supervision control and data acquisition station and several remote locations The SCADA system is connected to the remote locations via a model or other wireless or wired network Switch MTQ22 UMC UMC I 23 5 A Motor On Fault Firewall Gateway etc MTQ22 UMC Firewall Gateway etc Radio or other communication link ModbusTCP Client for on site control Local Panel PC Remot...

Page 16: ...all the new hardware The required driver inf file is part of the software package After startup of the application the screen is split into three areas left middle and right In the left area you can add as many MTQs as you have in your project In the middle area the configuration parameters per MTQ22 FBP 0 are displayed You can change them offline or online The right area shows a short help text S...

Page 17: ...lso be set manually Device Settings Up to four FBP devices can be connected to the MTQ22 FBP 0 For each port the connected device type or NONE must be specified The MTQ22 FBP 0 then monitors the presence of the configured FBP device Position Supervision The MTQ22 FBP 0 detects accidental permutation of devices connected to it Therefore a specific address 1 254 has to be set per port which must mat...

Page 18: ...h data type boolean values or analog values of each module This requires sending several Modbus telegrams to the dedicated addresses Access to the data of all connected devices with one MODBUS telegram ordered by module connected to port 1 4 Access to the data of all connected devices with one MODBUS telegram ordered by data type DI AI Diagnosis or DO AO MTQ22 Status Data Address Data Size Access ...

Page 19: ...x0C00 dec 3072 0x0C20 dec 3104 0x0C40 dec 3136 0x0C60 dec 3168 Diagnosis data of connected device 0 16 registers Read 0x1000 dec 4096 0x1010 dec 4112 0x1020 dec 4128 0x1030 4144 Digital Inputs DI 0 16 registers 0 32 bytes Read 0x1800 dec 6144 0x1810 dec 6160 0x1820 dec 6176 0x1830 dec 6192 Digital Outputs DO 0 16 registers 0 32 bytes Write Read 0x2000 dec 8192 0x2100 dec 8448 0x2200 dec 8704 0x230...

Page 20: ...s field has to be set to zero Only word access is supported in this address range Access to all data ordered by data type For performance reasons some applications might require access to the entire I O data with one Modbus TCP telegram This access method makes it possible to read or write data from all devices ordered by data type Address Data Length Access 0x5000 dec 20480 Input Data Block DI1 D...

Page 21: ... DI AI Diag 24 Bytes 12 Words Command Data DO AO 12 Bytes 6 Words Individual data access by device This method makes it possible to individually access data from a connected device via single registers or groups of registers Address for data access to device connected to port Data Length Access 1 2 3 4 0x0C00 0x0C20 0x0C40 0x0C60 Diagnosis 4 Words 8 Bytes each UMC Read 0x1000 0x1010 0x1020 0x1030 ...

Page 22: ... Bit 15 Word oriented access to the command data of UMC100 according to the UMC100 manual section A1 Parameters and Data Structures on a Fieldbus UMC at port 1 UMC at port 2 UMC at port 3 UMC at port 4 Bit 7 Bit 15 Bit 23 Bit 31 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit1 Bit 0 Bit 8 Bit 16 Bit 24 Address 0x1800 dec 6144 0x1810 dec 6160 0x1820 dec 6176 0x1830 dec 6192 Fault Reset Auto Mode Prepare Emergenc...

Page 23: ...0 Low Byte Run Time Excee ded1 Out of posi tion1 Torque Open1 Torque Closed1 End Pos Open1 End Pos Closed1 High Byte 0x2006 dec 8198 0x2106 dec 8454 0x2206 dec 8704 0x2306 dec 8966 U Imbal warn U Imbal trip Under voltage warn Under voltage trip Under power warn Under power trip Over power warn Over power trip Low Byte Earth fault warning Earth fault trip Cooling time running THD warning No start p...

Page 24: ...gered from Multi function input DI0 Trip Warning from AuxFault function block input 62 0x0C02 dec 3074 0x0C22 dec 3106 0x0C42 dec 3138 0x0C62 dec 3168 THD Warning Voltage out of spec1 Overload power Underload power1 Cooling Time Running Just one start left Num Starts Overrun 0x0C03 dec 3075 0x0C23 dec 3107 0x0C43 dec 3139 0x0C63 dec 3169 Extended diagnosis is available1 Parameter out of range Faul...

Page 25: ... dec 12331 U Imbal warn U Imbal trip Under voltage warn Under voltage trip Under power warn Under power trip Over power warn Over power trip Earth fault warning Earth fault trip Cooling time running THD warning No start possible No start possible More than one start left 0x3008 dec 12296 0x3014 dec 12308 0x3020 dec 12320 0x302C dec 12332 CB missing PTC wiring failure PTC hot Pre warn therm model L...

Page 26: ...t Auto Mode Prepare Emergency Start Run Forward Opening Off Run Reverse Closing UMC100 DO2 UMC100 DO1 Auto Mode UMC100 24VDC Out Run Fast Forward 0x4001 dec 16385 0x4007 dec 16391 0x400D dec 16397 0x4013 dec 16403 VI15x DO0 DX1xx DO3 DX1xx DO2 DX1xx DO1 DX1xx DO0 0x4002 dec 16386 0x4008 dec 16392 0x400E dec 16398 0x4014 dec 16404 Analog word 0x4003 dec 16387 0x4009 dec 16393 0x400F dec 16399 0x401...

Page 27: ...510 DX1xx DI7 DX1xx DI6 DX1xx DI5 DX1xx DI4 DX1xx DI3 DX1xx DI2 DX1xx DI1 DX1xx DI0 Run Time Exceeded1 Out of Position Torque Open Torque Closed End Pos Open End Pos Closed 0x500A dec 20490 0x5011 dec 20497 0x5018 dec 20504 0x501F dec 20511 U Imbal warn U Imbal trip Under voltage warn Under voltage trip Under power warn Under power trip Over power warn Over power trip Earth fault warning Earth fau...

Page 28: ...ency start Run Forward Opening Off Run Reverse Closing UMC100 DO2 UMC100 DO1 UMC100 DO0 UMC100 24VDC Out Run Fast Forward 0x6001 dec 24577 0x6003 dec 24579 0x6005 dec 24581 0x6007 dec 24583 VI15x DO0 DX1xx DO3 DX1xx DO2 DX1xx DO1 DX1xx DO0 0x6008 dec 24584 0x600C dec 24588 0x6010 dec 24592 0x6014 dec 24596 Analog word 0x6009 dec 24585 0x600D dec 24589 0x6011 dec 24593 0x6015 dec 24597 Analog word ...

Page 29: ...cted Only for intelligent devices like UMC or PST Not for passive sensors MTQ22 FBP 0 Status LED RDY General Status Explanation Green on Normal Red blinking Minor error e g wrong configuration or IP address already available in the network Red on Major internal fault If the error is permanent after reboot the device must be replaced LED TCP Communication Status Explanation Green blinking Waiting f...

Page 30: ...supported device was connected to the MTQ22 FBP 0 See the section Overview Supported FBP Devices for a list 3 Communication Fault on Module Port Communication to a FBP device was established but was lost again Check the FBP device Check that the FBP device is powered Check that the drawer is inserted in a withdrawable system 4 Address mismatch The configured device address and the real FBP device ...

Page 31: ...ength to 3 m Marks Approvals CE cUL Further in preparation Ask your local sales unit representative for other marks approvals Operation altitude above sea level max 2000 m For higher altitudes please contact your local sales unit EMC Measurement of radiated and conducted interference according to EN61131 2 CISPR16 2 3 Class A Electrostatic discharge according to IEC 61000 6 2 8 kV air discharge 6 ...

Page 32: ...in the MRP master Response time of a ModbusTCP request to IO data 1 ms typically Response time of a ModbusTCP request to parameter data and maintenance counters 3 ms typically Max concurrent Modbus TCP connections 4 Ethernet interfaces 2 internal two port switch Supported Ethernet topologies Star ring bus daisy chain Supported Bitrate 10 MBit s 100 MBit s LLDP Naming of Ethernet ports E1 Port_002 ...

Page 33: ...e and outside 1SAJ929200R0001 ETHTB FBP 4 Terminal set X1 X4 for Ethernet FBP 4 pcs package 1SAJ929200R0002 ETHTB FBP 50 Terminal set X1 X4 for Ethernet FBP 50 pcs package 1SAJ929230R0015 CPD23 150 Cable Ethernet interface UMC100 3 length 1 5 m 1SAJ929230R0030 CPD23 300 Cable Ethernet interface UMC100 3 length 3 m 33 UNIVERSAL MOTOR CONTROLLER UMC100 3 MTQ22 FBP 0 MODBUS TCP MANUAL ...

Page 34: ...ata Link Data MTQ22 Port 4 X1 X2 X3 X4 X5 X6 E1 E2 1 77 3 54 3 8 45 90 96 mm inch Pin 6 nc 5 0V blue 4 VCC brown 3 Rx black 2 Tx gray 1 Diag white 1 5 m 59 1 6 1 M12 A coded female 5 pol CDP17 6 1 6 1 1 6 CDP18 M12 A coded female 5 pol CDP19 CDP23 1 0 m 39 4 1 5 m 3 0 m 59 1 118 1 34 UNIVERSAL MOTOR CONTROLLER UMC100 3 MTQ22 FBP 0 MODBUS TCP MANUAL ...

Page 35: ...regard to purchase orders the agreed particulars will take precedence ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbid...

Reviews: