6

Mounting / Installation

Pos: 80 /B usch-J aeg er (Neus truk tur )/M odul -Strukt ur/O nline -Doku me ntatio n/Siche rheit  (- -> Fü r alle D oku ment e < --) /War nhinweis e/Siche rheit  - Nie ders pan nun gs- und  230  V-Leit ung en @  18\ mod _13 026 178 214 91_1 5.d ocx @  103 465  @  @  1

Warning

Electric voltage!

Risk of death and fire due to electrical voltage of 100-240 V.

– 

Low-voltage and 100-240 V cables must not be installed together in

a flush-mounted socket!

In case of a short-circuit there is the danger of a 100-240 V load on

the low-voltage line.

Pos: 81 /B usch-J aeg er  (Neus truk tur )/M odul -Strukt ur/O nline -Doku me ntatio n/Siche rheit  (- ->  Fü r alle D oku ment e < --) /War nhinweis e/Siche rheit  -  Fachk enn tnisse  @ 18 \mo d_1 302 774 384 017_ 15. docx @  10 356 4 @ 2  @ 1

6.1

Requirements for the electrician

Warning

Electric voltage!

Install the device only if you have the necessary electrical engineering

knowledge and experience.

• 

Incorrect installation endangers your life and that of the user of the

electrical system.

• 

Incorrect installation can cause serious damage to property, e.g.

due to fire.

The minimum necessary expert knowledge and requirements f or the

installation are as follows:

• 

Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1.

Disconnect from power;

2.

Secure against being re-connected;

3.

Ensure there is no voltage;

4.

Connect to earth;

5.

Cover or barricade adjacent live parts.

• 

Use suitable personal protective clothing.

• 

Use only suitable tools and measuring devices.

• 

Check the type supply network (TN system, IT system, TT system)

to secure the following power supply conditions (classic connection

to ground, protective earthing, necessary additional measures,

etc.).

Pos: 82 /Di nA4 - A nleitu ngen  Onlin e/In halt/KNX/Do orEnt ry/M onta ge/ Mont age hinweis e - Allg emei n @ 1 9\m od_ 131 056 367 047 8_15 .docx  @ 1 077 43 @  2 @  1

Summary of Contents for M2304

Page 1: ...Welcome M Pos 2 DinA4 Anl eitun gen Online Inh alt KNX Doo rEntry 832 20 AP xxx Tit elblat t 832 20 AP xxx ABB 1 9 m od_ 132 3249 806 476 _15 docx 11 108 4 1 M2304 Video distributor E nde der Liste f...

Page 2: ...ic hnis 19 mod _13 206 490 4438 6_1 5 d ocx 109 653 1 1 Safety 3 2 Intended use 3 3 Environment 3 3 1 ABB devices 3 4 Operation 5 4 1 Control elements 5 4 2 Operating modes 5 5 Technical data 7 6 Moun...

Page 3: ...h components from this system Device M2304 can be mounted easily inside flush mounted box or surface mounted on the wall by one screw Pos 10 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku...

Page 4: ...al requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH ordinance and law for the implement...

Page 5: ...32 128 536 05_ 15 d ocx 103 673 1 Fig 1 Overview of control buttons No Functions 1 Bus in out 2 4 outputs for indoor stations or risers For details see Operating modes 3 Terminal resistor ON OFF In vi...

Page 6: ...lements A In a building a video distributor divides the video signal into 4 branches in connection with the indoor stations B For a residential complex the video distributor can be used to divide the...

Page 7: ...AP x xx 1 8 m od_ 130 321 285 4559 _15 docx 1 037 05 1 Designation Value Operating temperature 25 C to 55 C Storage temperature 40 C 70 C Protection IP 20 Single wire clamps 2 x 0 28 mm 2 x 1 mm Fine...

Page 8: ...18 mo d_1 302 774 384 017_ 15 docx 10 356 4 2 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and exp...

Page 9: ...supplies to avoid interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bu...

Page 10: ...684 8_1 5 doc x 1 110 98 1 Device M2304 can be easily mounted in the flush mounted box or surface mounted on the wall by a screw Mounted with flush mounted box Mounted on the wall Pos 83 B usch J aeg...

Page 11: ...Ba ckcove r We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of or...

Reviews: