Environment
Operating Instructions VER:1.3
│
5
3.3
Terminal description
Fig. 2
No
Function
1
Connector for device software update
2
Rotary switch to set the address of outdoor station (1-9)
3
Set feedback tone of pushbutton ON/OFF
4
Set general call to all indoor stations in one family: ON/OFF
If GC=ON, press button 1/button 2, all IS ring
5
Configuration function of 1st/2nd round pushbutton
5A mini video outdoor station with one pushbutton
3 -> OFF; 4 -> OFF = Call IS 001
3 -> ON; 4 -> OFF = Switch on light
3 -> OFF; 4 -> ON = Call guard unit
3 -> ON; 4 -> ON = Call IS 001
5B mini video outdoor station with two pushbuttons
3 -> OFF; 4 -> OFF = Call IS 001/002
3 -> ON; 4 -> OFF = Switch on light/call IS 001
3 -> OFF; 4 -> ON = Call guard unit/call IS 001
3 -> ON; 4 -> ON = Call IS 001/call IS 002
1
2
3
4
5
6
7
8
9
10
11
12
13