Commissioning

Operating Instructions VER:1.3

17

6

Commissioning

6.1

Configure functions of the 1st/2nd pushbutton

Fig. 14

No

Function

1

3-> OFF, 4-> OFF

2

Call apartment 001

3

Call apartment 002

Tab.5

Fig. 15:

No

Function

1

3-> OFF, 4-> ON

2

Call guard unit

3

Call apartment 001

Tab.6

DIP

3

4

0

5

001

002

DIP

3

4

0

5

001

G

Summary of Contents for M2131xPx-A series

Page 1: ...VER 1 3 20 06 2017 Operating Instructions ABB Welcome Mini video outdoor station M2131xPx A M2136xPx A ...

Page 2: ... Installation 9 5 1 Requirement for the electrician 9 5 2 Mounting 10 5 2 1 Preparation 10 5 2 2 Surface mounting 10 5 2 3 Flush mounting 11 5 2 4 Cavity wall installation 13 5 2 5 Dismantling 15 5 2 6 Replace the nameplate 15 5 2 7 Installation situations 16 6 Commissioning 17 6 1 Configure functions of the 1st 2nd pushbutton 17 6 2 Setting general call function 19 7 Operation 20 7 1 Manage ID ca...

Page 3: ...der the protection of the environment Used electric and electronic devices must not be disposed of with household waste The device contains valuable raw materials that can be recycled Therefore dispose of the device at the appropriate collecting facility 3 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing m...

Page 4: ...rating Instructions VER 1 3 4 3 2 Front overview Fig 1 No Function 1 Light sensor 2 Infrared LED 3 Indicator LED ring call and door open 4 Speaker and microphone integration 5 Pushbutton 6 Nameplate Tab 1 1 2 3 4 5 6 ...

Page 5: ...ily ON OFF If GC ON press button 1 button 2 all IS ring 5 Configuration function of 1st 2nd round pushbutton 5A mini video outdoor station with one pushbutton 3 OFF 4 OFF Call IS 001 3 ON 4 OFF Switch on light 3 OFF 4 ON Call guard unit 3 ON 4 ON Call IS 001 5B mini video outdoor station with two pushbuttons 3 OFF 4 OFF Call IS 001 002 3 ON 4 OFF Switch on light call IS 001 3 OFF 4 ON Call guard u...

Page 6: ...OM NC NO as default lock Default lock is controlled by unlock button on IS 8 Plug in clamps a b for bus connection 9 Plug in clamps Exit GND for exit button 10 Plug in clamps Lock GND for door opener 11 Plug in clamps COM NC NO for floating output door opener 12 Rotary switch to adjust default door lock release time 1 10s 13 Rotary switch to adjust loudspeaker volume Tab 2 ...

Page 7: ... AC Type A Type B Electrical strike lock 24 V Power on to open 24 VDC AC Type B Electrical rim lock 12 V Power on to open 12 VDC Type A Type B Electrical mortise lock Power off to open 12 VDC Type C Magnetic lock Power off to open 12 24 V DC Type C Tab 3 Fig 3 a b EXIT GND LOCK COM NO NC a b EXIT GND LOCK COM NO NC a b EXIT GND LOCK COM NO NC PS Type A Type B Type C PS ...

Page 8: ...Operating temperature 40 C 70 C Protection IP 54 Power supply door opener Lock GND 18 V 4 A impulsive 250 mA holding Floating supply door opener COM NC NO 30 V DC AC 1A Single wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Fine wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Bus voltage 20 30 V DC Tab 4 ...

Page 9: ...dge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no volt...

Page 10: ...Mounting Installation Operating Instructions VER 1 3 10 5 2 Mounting 5 2 1 Preparation Use gloves to protect yourself from being cut Fig 4 5 2 2 Surface mounting Fig 5 99 mm 26 5 mm 78 mm 168 mm 147 mm ...

Page 11: ...ation Operating Instructions VER 1 3 11 5 2 3 Flush mounting Product dimension Fig 6 Mounting without pre installation box Fig 7 90 mm 105 mm Front view Back view Side view 180 mm 168 mm 43 mm 90 mm 168 mm 33 mm 10 mm ...

Page 12: ...you must control the embedded depth ensuring the outer edge of the lower cover can be fully attached to the wall but should not leave a large gap between the exposed parts of the face shell and the wall after the installation of the equipment Do not install in raining humid or dusty environments and not near objects of high temperature or strong corrosion 99 mm 99 mm 45 mm 174 mm 174 mm TOP ...

Page 13: ...n Operating Instructions VER 1 3 13 5 2 4 Cavity wall installation Product dimension Fig 9 Installation dimension Fig 10 90 mm 105 mm Front view Back view Side view 180 mm 168 mm 43 mm 7 mm 29 mm 92 mm 97 mm 170 mm 120 mm ...

Page 14: ...Mounting Installation Operating Instructions VER 1 3 14 Cavity wall installation Fig 11 ...

Page 15: ...Mounting Installation Operating Instructions VER 1 3 15 5 2 5 Dismantling Fig 12 5 2 6 Replace the nameplate Fig 13 out TT L N 39 mm 35 mm in TT L N ...

Page 16: ...ion situations Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station Lamps or direct light sources ...

Page 17: ...issioning 6 1 Configure functions of the 1st 2nd pushbutton Fig 14 No Function 1 3 OFF 4 OFF 2 Call apartment 001 3 Call apartment 002 Tab 5 Fig 15 No Function 1 3 OFF 4 ON 2 Call guard unit 3 Call apartment 001 Tab 6 DIP 3 4 0 5 001 002 DIP 3 4 0 5 001 G ...

Page 18: ...ting Instructions VER 1 3 18 Fig 16 No Function 1 3 ON 4 OFF 2 Switch on light 3 Call apartment 001 Tab 7 Fig 17 No Function 1 3 ON 4 ON 2 Call apartment 001 3 Call apartment 002 Tab 8 DIP 3 4 0 5 001 DIP 3 4 0 5 002 001 ...

Page 19: ...nt 001 all 4 indoor stations different address ring 3 Call apartment 002 all 4 indoor stations different address ring Tab 10 If the call forward function has been set at the indoor station this function will not work well For example 001IS has set call forward to 002 IS when press 1st round pushbutton on OS to call 001 IS if 001 IS doesn t answer the call in 5s it will not transfer to 002 IS DIP 2...

Page 20: ...d Function Command Indicated color of door open Enroll user Swipe admin card 1x Orange flash 1x Swipe user card 1x Green Delete user Swipe admin card 2x Orange flash 2x Swipe user card 1x Green Enroll new admin Swipe admin card 3x Orange flash 3x Swipe new admin card 1x Green Delete admin Swipe admin card 4x Orange flash 4x Swipe other admin card 1x Green Delete all users Swipe admin card 5x Orang...

Page 21: ...door open Reset to factory default Press and hold the 1st button for 3 s to enter configuration mode Press and hold the 1st button for 10 s to reset to factory default Reboot the device 3 LED green cycle flash 3 LED OFF Door open LED red green orange cycle flash Tab 15 Technical data of ID card Work frequency Standard Support ID card protocol 125KHz ISO18000 2 EM4100 EM4205 EM4305 EM4450 TK4100 T5...

Page 22: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 23: ... 3861 1010 F 84 4 3861 1009 ABB KSA Electrical Industries Co Ltd P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str RU T 7 495 777 2220 F 7 495 777 2220 ABB Malaysia Sdn Bhd Block A Level 2 Lot 608 Jalan SS13 IK 47500 Subang Jaya Selangor T 60 3 5628 4888 F 60 3 5635 8200 ABB Hong Kong Ltd 3 Dai Hei Street Tai Po Industri...

Reviews: