L ST4 0 0 |
U LT R A S O N I C L E V EL T R A N SM I T T ER
| O I/L S T4 0 0 - EN R E V. E
31
General purpose 15m Sensor
• Maximum measuring length (ML) 50ft / 15 m
• Application: general use non-corrosive liquid
4.3 in
110 mm
3.2 in
80 mm
Ø
77.5 mm
25.4 mm
77.2 mm
Ø
92.2 mm
Thread:
1" NPT x 0.94" long (ref.)
Foam face 15m sensor
• Maximum measuring length 50ft / 15m.
• Application: general use in solid materials.
Corrosion resistant 15m sensor
• Maximum measuring length 50ft / 15m
• Application: corrosive liquid
NOTICE
Corrosion resistance doesn't include sensor cable - need
special protection of cable when required.
General purpose 30m sensor
• Maximum measuring length 100ft / 30m
• Application: general use non-corrosive liquid