6.5.2 Output Size
Parent
Output Size
belongs to the type
PROFINET Internal Device
, in the topic
I/O System
.
Cfg name
OutputSize
Description
The parameter
Output Size
is used to configure the output slot configuration of
the PROFINET internal device.
Usage
The parameter
Output Size
is only valid for the PN_Internal_Device. It will configure
the output slot size for the PROFINET internal device. This size must match the
connecting PLC’s or other PROFINET controller’s defined input slot size. For more
information, see
Input and output size on page 30
.
Prerequisites
The option
PROFINET Controller/Device
or
PROFINET Device
must be installed.
Default value
The default value is 64 bytes (512 signal bits).
Allowed values
8, 16, 32, 64, 128 or 256 bytes (64, 128, 512, 1024 or 2048 signal bits).
68
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
6 System parameters
6.5.2 Output Size