4 Repair
4.6.3. Replacement of motor, axis 3
3HAC026876-001 Revision: C
318
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
Replacement of the motor axis 3 (Foundry Prime)
Robots working with Foundry Prime and that have the special tightness for this application
require special repair routines to maintain the tightness level.
The repair must be done according to the previous repair procedures with the following
additions.
20.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
cause injury or damage! on page 33
.
Action
Note
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
2. Remove the motor according to step 2 - 4 in
3. Remove the cover for connector access on top of
the motor by unscrewing its four attachment
screws.
xx0600002874
•
A: Attachment screw
•
B: Air hose
•
C: Top cover
•
D: Motor unit
A
C
D
B
Continued
Continues on next page