5.8 Updating revolution counters
Introduction
This section describes how to do a rough calibration of each manipulator axis by
updating the revolution counter for each axis, using the FlexPendant.
Step 1 - Manually moving the manipulator to the synchronization position
Use this procedure to manually move the manipulator to the calibration position.
Note
Calibration should be performed by specially trained personnel.
Note
Action
See
Calibrating axis 1-3 on page 242
, steps
1 to 6.
Manually move the manipulator to the cal-
ibration position for axes 1-3
1
See
Calibrating axis 4 on page 245
, steps 1
to 4.
Manually move the manipulator to the cal-
ibration position for axis 4
2
Continue with step 2,
revolution counter with the FlexPendant
on page 248
3
Step 2 - Updating the revolution counter with the FlexPendant
Use this procedure to update the revolution counter with the FlexPendant (IRC5).
Action
On the
ABB
menu, tap
Calibration
.
xx1500000942
1
Continues on next page
248
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
5 Calibration information
5.8 Updating revolution counters
Summary of Contents for IRB 360-1/800
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 156: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 258: ...This page is intentionally left blank ...
Page 276: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 283: ......