… 13 Specification
ProcessMaster – Material load for process connections
The limits of the permissible measuring medium temperature
(T
medium
) and permissible pressure (P
medium
) are calculated on
the basis of the liner and flange material used in the device (see
device name plate).
Minimum permissible operating pressure
The following tables show the permissible minimum operating
pressure (P
medium
) as a function of the measuring medium
temperature (T
medium
) and the liner material.
Design Level ‘A’
Lining material
Nominal diameter
P
medium
[mbar abs]
T
medium
*
Hard rubber
DN 25 to DN 2000
(1 to 80 in)
0
< 85 °C (185 °F)
< 80 °C (176 °F)**
Soft rubber
DN 50 to DN 2000
(2 to 80 in)
0
< 60 °C (140 °F)
PTFE
DN 10 to DN 600
(
⅜
to 24 in)
270
< 20 °C (68 °F)
400
< 100 °C (212 °F)
500
< 130 °C (266 °F)
Thick PTFE
DN 25 to DN 80
(1 to 3 in)
0
< 180 °C (356 °F)
DN 100 to DN 250
(4 to 10 in)
67
< 180 °C (356 °F)
DN 300 (12 in)
27
< 180 °C (356 °F)
PFA
DN 3 to DN 200
(¹
⁄
₁₀
to 8 in)
0
< 180 °C (356 °F)
ETFE
DN 25 to DN 600
(1 to 24 in)
100
< 130 °C (266 °F)
Ceramic carbide
DN 25 to DN 1000
(1 to 40 in)
0
< 80 °C (176 °F)
Linatex**
DN 50 to DN 600
(6 to 24 in)
0
< 70 °C (158 °F)
* For CIP/SIP cleaning, higher temperatures are permitted for limited time
periods; refer to
Maximum permissible cleaning temperature
on page 131.
** Only for China production site
Design level ‘B’
Lining material
Nominal
diameter
P
medium
[mbar abs]
T
medium
*
PTFE
DN 25 to DN 300
(1 to 12 in)
270
< 20 °C (68 °F)
400
< 100 °C (212 °F)
500
< 130 °C (266 °F)
* For CIP/SIP cleaning, higher temperatures are permitted for limited time
periods; refer to
Maximum permissible cleaning temperature
on page 131.
Liner approvals on request; please contact ABB.