HVC-R 100/150 E-Bus Charger Installation Guide
Document: v0.4 / Document No.: TBA | Date: 11-08-2021 Page
117
of
131
8.
Technical specification
8.1. Electrical specification od a complete 100 kW system
AC Input Power Cabinet
Supply voltage
3-phase, 400 V AC: PE, L1, L2, L3
Input voltage range
400 V AC ± 10%
Input frequency range
50 Hz ± 4%
Maximum power dissipation
117 kVA
Power factor (cos
ᵠ
)
≥
0.95
Standby power consumption
< 60 W
Efficiency
94% and 96% in power spectrum between 20% and
100% of full power
Maximum input current
177 A AC
Nominal input current
159 A AC
Earth Leakage Current Protection
AC 300 mA (RCD integrated in HVC150(S))
AC 30 mA (RCD integrated in ACS Control Module)
Short Circuit Capacity
25 kA
AC power connection
240 mm
2
(max)
AC Input Dual Depot Charge Box
Supply voltage
1-phase: GND, L, N
Input voltage
230 V AC ± 10%
Input frequency range
47 - 63 Hz ± 1%
Nominal input current
2.17 A AC
Earth Leakage Current protection
AC 30 mA
DC output
Maximum output power
100 kW
Output voltage range
150 – 850 V DC
Maximum output current
166 A DC