3.2
Inspection work includes preventive visual controls plus monitoring and
measuring work before and during commissioning. Inspections help detect
changes to the turbocharger. Machine damage can be avoided.
Inspection before commissioning
τ
Check for correct functioning.
τ
Inspect for damage.
τ
Check oil filter for cleanliness before commissioning.
CAUTION
Contaminated oil
Particles of dirt and solid matter in the oil can cause serious damage to
the machine or property.
τ
During initial commissioning and after all service work, the complete
lubricating system must be flushed thoroughly with warm oil.
τ
When running in the engine and after all service work on the lubricat-
ing system, special running-in filters must be used.
τ
Check oil pressure in oil supply lines.
CAUTION
Prelubrication
Serious machine or property damage might result if the turbocharger is
not supplied with oil when the engine is starting.
τ
Activate prelubrication device before starting engine.
τ
Check whether the warning plates are present and legible.
τ
Check whether the protective sheets have been removed.
3.2
3.2.1
Monitoring devices
Filter mat
Lubricating system
Warning plates on tur-
bocharger