Operation Manual / TPS44-F.. - TPS61-F..
Operation
4
Speed measurement
4.4
Page 52
© Copyright 2016 ABB. All rights reserved.
A
ug
us
t2
01
7
H
ZT
L2
41
2_
E
N
R
ev
is
io
n
F
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Risk of burning. During operation, the cable connector and the speed
sensor can reach temperatures exceeding 100 °C.
τ
Wear safety gloves when removing the cable connector and speed
sensor.
Wear safety gloves to protect against thermal hazards.
τ
Reduce engine performance to the idling speed, then stop the engine.
τ
Switch off the lubricating oil supply to the turbocharger.
τ
Disconnect the cable connector from the speed sensor.
τ
Screw out defective speed sensor.
τ
Screw in a new speed sensor up to the limit block.
τ
Adhere to tightening torque.
Part number
TPS44
TPS48
TPS52
TPS57
TPS61
86505
15 Nm
15 Nm
15 Nm
15 Nm
15 Nm
4.4.2