Mothballing the turbocharger
10
Taking the engine out of operation for
up to 12 months
10.1
Page 135
© Copyright 2016 ABB. All rights reserved.
D
ec
em
ber
2016
H
ZT
L2481_
EN
R
ev
is
ion
B
Mothballing the turbocharger
Taking the engine out of operation for up to
12 months
10.1
Condition of engine lubricating oil
The turbocharger normally remains mounted on the engine. Mothballing a
turbocharger depends on the condition of the lubricating oil:
If the total acid number (TAN) is lower than 2 mg KOH/g, no measures
have to be taken.
If the engine lubricating oil is replaced by preserving oil before taking
the engine out of operation and this is circulated by the pre-lubrication
pump, no measures have to be taken. Any remaining old engine oil will
therefore be flushed away and the bearing sections largely protected
against corrosion.
Mothballing measures
WARNING
Handling operating materials and supplies
Swallowing or inhaling vapours of operating materials and supplies or
contact with them may be harmful to health.
Do not breathe in these substances and avoid contact with the skin.
Ensure proper ventilation.
Observe the information in the material safety data sheet for the op-
erating materials and supplies.
Comply with local legislation.
Wear safety goggles.
Wear safety gloves to protect against mechanical hazards.
Wear a respiratory mask to protect against gases.
10
10.1