Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
Operation
4
Speed measurement
4.4
Page 43
© Copyright 2016 ABB. All rights reserved.
D
ec
em
ber
2016
H
ZT
L2481_
EN
R
ev
is
ion
B
The difference between the highest and the lowest turbocharger speed
must not be more than 3 % relative to the speed limit n
Bmax
.
If this permissible range of difference is exceeded, the following steps
must be carried out:
Reduce engine performance immediately until the highest turbo-
charger speed no longer exceeds 70% of n
Bmax
.
If the engine cannot be stopped, continue to run at this reduced engine
performance or turbocharger speed.
If the turbocharger surges continuously, engine performance must be
reduced further.
Measure the temperatures in the air and gas lines to and from the tur-
bochargers and compare them with standard values.
If the engine can be stopped for a short time:
Inspect the air and gas lines as well as the turbocharger and eliminate
any problems.
In any event, it is recommended that you contact the nearest ABB
Turbocharging Service Station.
Assembly
If the speed sensor is not fitted on the turbocharger, the following proce-
dure must be adopted to fit it:
Engine and turbocharger are not running.
The turbocharger lubricating system is switched off.
Remove screw plug (42047) from bearing casing.
NOTICE
Part position
The position of the screw plug for measuring the speed is marked "n"
on the bearing casing.
Screw in speed sensor (86505) as far as it will go and tighten to torque
specified in table. (See chapter Table of tightening torques.)
Connect speed sensor using cable connector (86515).
4.4.2