Operation Manual / TPS48-D/E.. - TPS61-D/E..
Operation
4
Speed measurement
4.4
Page 52
Apr
il 2015
H
ZT
L2410_
EN
R
ev
is
ion
D
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Risk of burning. During operation, the cable connector and the speed
sensor can reach temperatures exceeding 100 °C.
Wear safety gloves when removing the cable connector and speed
sensor.
Wear safety gloves against thermal risks.
Reduce engine performance to the idling speed, then stop the engine.
Switch off the lubricating oil supply to the turbocharger.
Disconnect the cable connector from the speed sensor.
Screw out defective speed sensor.
Screw in a new speed sensor up to the limit block.
Adhere to tightening torque.
Part number
TPS48
TPS52
TPS57
TPS61
86505
15 Nm
15 Nm
15 Nm
15 Nm
4.4.2
© Copyright 2015 ABB. All rights reserved.