![ABB HD5-B-101 Original Instructions Manual Download Page 22](http://html.mh-extra.com/html/abb/hd5-b-101/hd5-b-101_original-instructions-manual_3045367022.webp)
22
9.
TECHNICAL DATA
Manufacturer
Address
ABB Electrification Sweden AB
SE-721 61 Västerås, Sweden
Power supply
Operational voltage
30 VDC, AS-i Bus, tolerance 26 - 31,6 VDC
Overall power consumption
<150 mA
General
Protection class
IP65
Ambient temperature for during operation -10°C
(no buildup of ice)
up to +55°
C (no direct sunlight)
Ambient temperature for storage
-20°C
(no buildup of ice)
up to
+70°
C (no direct sunlight)
Dimensions
See drawing in section 12 “dimensions”
Weight
approx. 200 g without connection cable
Material
Housing: Fiberglass reinforced plastic, PPH G30
Operating buttons: TPE
Actuating force
enabling button
approx. 20 N, 1
2
approx. 45 N, 2
3
Actuating force
additional buttons
approx. 3 N, additional buttons 1 and 2
approx. 7 N, additional buttons 3 and 4
Mechanical /electrical durability of
enabling button
1 x 10
6
switching cycles, position 1
position 2
1 x 10
5
switching cycles, position 2
position 3
Mechanical reliability B
10D,
enabling button
B
10D
: 2 x 10
6
, position 1
position 2
position 1
B
10D
: 968,000, position 1
position 3
position 1
Mechanical /electrical durability of
emergency stop button
5 x 10
4
switching cycles
Mechanical reliability B
10d,
emergency stop button
B
10D
: 250,000
Mechanical durability of
additional button 1
2 x 10
6
switching cycles
Mechanical durability of
additional buttons 2/3/4
5 x 10
4
switching cycles
Connection
M12 connector 5 pin, A coded