Setup and function
Product manual 2CKA001473B9364
│
9
3.3
Overview of types
Article no.
Product name
Colour
HA-S-1-WL
Radiator thermostat, Basic
White
HA-S-2-WL
Radiator thermostat, Comfort
White
Table 2: Overview of types
3.4 Functions
The following table provides an overview of the possible functions and applications of the
device:
Icon of the user interface
Information
Name:
Radiator thermostat, Basic / Radiator
thermostat, Comfort
Type:
Actuator
Made available by:
Radiator thermostat Basic / Comfort
Function:
Regulates free@home radiator
thermostats (actuating drives)
Table 3: Overview of functions
Basic functions of Basic
The Basic version of the device has two push-buttons on top of the device:
■
OFF
(off button): Switches the device into the OFF mode. This means that the temperature
is no longer regulated. The frost protection function and valve protection function are active.
■
Comfort
: Switches the device into Comfort mode. The temperature is regulated to the
setpoint value. The setpoint value can be set via a connected extension unit (e.g. a
free@home-Touch 7“ or a free@home room temperature controller) or via the ABB-
free@home
®
app.
Basic functions of Comfort
The Comfort version has two push-buttons on top of the device, as well as a rotary knob at the
front of the device:
■
ON/OFF
(off button): Switches the device into the OFF mode or Comfort mode. The
temperature is not regulated in the OFF mode. The frost protection function and valve
protection function are active. In Comfort mode the temperature is regulated to the setpoint
value. The setpoint value can be set locally via the rotary control element. The setpoint
value can also be set via a connected extension unit (e.g. a free@home-Touch 7“ or a
free@home room temperature controller) or via the ABB-free@home
®
app.
■
ECO
: This is used to switch over between Comfort and ECO mode. In ECO mode the
temperature is reduced by a pre-programmed value. Example: You are leaving the room for
a few hours; the room temperature is to be reduced to save energy; however, the room is
not to cool down completely.