19
2TLC172011M0205_B
5.11 Gateway Node Number
To use this function the gateway need software version 3.0 or higher.
The “plutoGatewayNode” command will set the gateway node number on Pluto bus. Normal this
node number is read from DIP-switch in the range of 0 – 3. With this parameter it’s possible to set
the node number from ABB robotic system in the
range of 0 – 16.
Note that node gateway node number above 7 maybe will need update of Pluto OS.
Name plutoGatewayNode
Type plutoGateway
Value
0 – 16
Value Gateway
Node
Number
0 Read
from
DIP-switch
1
Node Number 0
2
Node Number 1
3
Node Number 2
4
Node Number 3
5
Node Number 4
6
Node Number 5
7
Node Number 6
8
Node Number 7
9
Node Number 8
10
Node Number 9
11
Node Number 10
12
Node Number 11
13
Node Number 12
14
Node Number 13
15
Node Number 14
16
Node Number 15
Order 7
Path
6,20 64 24 00 30 13,D1,1
Service Set_Attribute_Single
(0x10)
5.12 Additional Data configuration
5.12.1 Additional Data
To use this function the gateway need software version 2.0 or higher.
The “plutoAddData_Nodexx” and “plutoAddData_IOxx” command will set configuration of
additional data area xx there the area can be 0-31.
Note these shall be written in pair!
Note don’t use “plutoExpected” when configuration of additional data!
Name plutoAddData_Node
xx
Name plutoAddData_IO
xx
Type plutoGateway
Type plutoGateway
Value
0 – 31 (Pluto node)
Value
0 – 255 (111 global data)
Order 6
Order 6
Path
6,20 64 24 00 30
yy
,D1,1
Path
6,20 64 24 00 30
zz
,D1,1
Service Set_Attribute_Single
(0x10)
Service Set_Attribute_Single
(0x10)