![ABB GAA330-M Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/abb/gaa330-m/gaa330-m_operating-instructions-manual_4424019.webp)
GAA330-M
EMISSION MONITORING SYSTEM | OI/GAA330-M-EN REV. C
19
Weight of the individual system components
Sheet steel cabinet (basic version)
Approx. 110 kg
Probe tube type 42, heated
8 kg
Filter unit, heated, with protective case
20 kg
Sample gas line type TBL01, heated
1 kg/m
Cooling unit
13 kg
Sound level
Ventilation fan
50 Hz Approx. 59 dB(A)
60 Hz Approx. 61 dB(A)
Cooling unit
Max. 61 dB(A)
Safety
Test
to EN 61010-1:2010
Overvoltage category
Power supply: II
Degree of pollution
2
Electromagnetic compatibility
Interference immunity Tested to EN 61326-1:2013. Inspection severity:
Industrial area, fulfills at least the rating to Table 2
of EN 61326.
Emitted interference
Tested to EN 61326-1:2013. Limit value class B for
interference field strength and interference voltage
is met.