![ABB FPTC-02 User Manual Download Page 58](http://html.mh-extra.com/html/abb/fptc-02/fptc-02_user-manual_2723058.webp)
Description
Example
value
Name
Index
Sets the time that is needed to coast
the motor to a standstill from maximum
process speed. If this time is not
known, it can be measured with Drive
composer pro PC tool when an encoder
is used for motor control (otherwise you
have to make sure that the motor shaft
has stopped rotating by other means,
eg, visually).
2000 ms
Time to zero
speed with
STO and mod-
off
STO.14
Acknowledgement is allowed after
coast stop in the STO, SSE and SS1
functions (when SBC is not used). If the
drive STO is activated or modulation
stopped while a monitoring safety
function is indicating “unsafe”, after this
time acknowledgement is allowed. For
example, if the drive modulation is lost
during SLS deceleration ramp, SLS OK
will be indicated after this time has
elapsed.
STO function: This parameter sets the
time after which the STO function is
completed and the STO completed in-
dication goes on. Parameter
defines the time after which the acknow-
ledgement is allowed. Adjust the value
according to application requirements.
When an encoder is used: This para-
meter is relevant only if there is an en-
coder failure and the FSO module activ-
ates the STO function.
SBC usage
Sets how the mechanical brake is used
together with the STO function.
None
STO SBC us-
age
SBC.11
In the safety functions described in this
manual, this feature is not used and
this parameter has value
None
.
58 Parameter settings
Summary of Contents for FPTC-02
Page 2: ......
Page 4: ......
Page 23: ... Layout 1 1 2 4 3 XSTO2 XSTO1 XWRN XFLT Retaining clips 1 Lock 2 Hardware description 23 ...
Page 28: ...28 ...
Page 37: ...2 3 1 4 Mechanical installation 37 ...
Page 38: ...38 ...
Page 48: ...48 ...
Page 64: ...64 ...
Page 70: ...70 ...
Page 78: ...78 ...
Page 89: ...Technical data 89 ...
Page 90: ...90 Technical data ...
Page 92: ...92 Technical data ...
Page 93: ...Check the latest version of the certificate in the ABB Library Technical data 93 ...