2CCF018900R0002-CH | AC Charger for Electric Vehicles, Model eCharger 35
3.5 Water
drainage
ABB eCharger 1x22kW
CUA4-F1T2L-32M3
CUA4-W1T2L-32M3
Electrical connection
400 V AC, 50-60 Hz,
32A, 3-phases, N, PE
Recommenced circuit breaker (MCB)
S 204 M-C 32 2CDS274001R0324
Wire cross section
Min. 5x6mm2 Cu; max. 5x10mm2 Cu
Fig. 22: Principle scetch and electric power supply 1x22kW
To avoid water drops coming from wet charge plugs throuth the socket, a
water drainage must be foreseen.
For wallmounted variants the water drainage is already installed. For floor
mounted variants one waterhose per socket is included in the delivery.
Scope of delivery
1 waterhose (1pc. per socket)
2 clamping spring (1pc. per socket)
Mounting (pole installations)
Attach the water hoses to the intended drainage at the socket using the
clamping spring. Plug in the water hoses in the intended holes into the
pole. If necessary, cut water hoses to proper length.
Fig. 23:
Montage Wasserablauf bei 2 Ladesteckern
L3R
PE
PE
N
L3
L2
L1