background image

Technical Reference Manual 

   

do

GATE

 - Installation instruction 

 

Connectors and button

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Reference Manual   | 1473-1-84

79

 

— 4 — 

   

Connectors and button 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution 

Risk of damaging the device ! 

If the power supply has been disconnected without stopping the device, risk of damaging the 
device is possible. Before unplugging power supply, make sure do

GATE

 is stopped. 

 

 
 

 

You must 
connect to LAN1 
for doGate 
configuration. 

Summary of Contents for doGATE

Page 1: ...1473 1 8479 13 03 2014 Technical Reference Manual doGATE Installation instruction geb ich doGATE DGT K AB ...

Page 2: ...473 1 8479 2 1 Technical data 3 1 1 Environmental characteristics 3 1 2 Mechanical characteristics 3 1 3 Electrical characteristics 3 2 Connectors and button 4 3 Networks 5 4 Installation 6 4 1 Using precautions 6 4 2 Power On Power Off 6 5 Scope of delivery doGATE box 7 6 Documentation 8 ...

Page 3: ... humidity 10 to 95 at 40 C without condensation Vibrations 1 5 g ms from 5 to 500Hz Resistance to shock 20G 11ms Stop 60G 1 2 Mechanical characteristics Parameter Vakue Material Aluminum alloy Mounting On table vertical or horizontal DIN rail via MDRC mounting kit Weight 2 kg Dimension 252 x 199 x 33 mm 1 3 Electrical characteristics Parameter Value Input voltage 10 VDC to 28 VDC Max power 25 W Pr...

Page 4: ...e Manual 1473 1 8479 4 2 Connectors and button Caution Risk of damaging the device If the power supply has been disconnected without stopping the device risk of damaging the device is possible Before unplugging power supply make sure doGATE is stopped You must connect to LAN1 for doGate configuration ...

Page 5: ...et BACnet ModBus IP KNX EIA 852 LAN2 Ethernet BACnet ModBus IP KNX EIA 852 LAN 1 default address 192 168 1 254 LAN 2 default address 192 168 2 254 RJ45 connectors wiring COM1 COM2 und COM3 Pin COM1 COM2 COM3 1 DSR NET NET 2 DCD NET NET 3 DTR 4 GND 5 RXD 6 TXD 7 CTS 8 RTS Wiring of DB9 connector for RS232 or RS485 Pin RS232 RS485 1 DCD NET 2 RXD 3 TXD 4 DTR 5 GND 6 DSR NET 7 RTS 8 CTS 9 Note Do not...

Page 6: ... natural ventilation Make sure to check input voltage and polarity before plugging the power supply Connect and disconnect peripherals after powering off doGATE Before unplugging power supply press Power button to stop doGATE IT IS RECOMMENDED TO USE AN UNINTERRUPTIBLE POWER SUPPLY IN ORDER TO AVOID MALFUNCTION OR DEVICE DETERIORATION Guaranty does not apply if doGATE has been opened 4 2 Power On ...

Page 7: ...8479 7 5 Scope of delivery doGATE box The doGATE box contains doGATE device station RJ45 DB9 wire Installation instruction CD ROM with documentations and software tools Software key paper sheet Note Configuration of the station is realized with doMOOV Dashboard software included on CD that must be installed on a Windows PC ...

Page 8: ...erence Manual doGATE Installation instruction Documentation Technical Reference Manual 1473 1 8479 8 6 Documentation The configuration documentation is delivered on the included CD ROM It is available in PDF format ...

Page 9: ...al changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not ...