102
Service
3ADW000195R0501 DCS800 Service Manual e e
Download text file:
De-energize the DCS800 electronics
Set jumper S5 on SCDS-CON-4 from position 1-2 to position 3-4
Energize the DCS800 electronics. In case the 7-segment display shows a
the firmware’s corresponding text file has to be downloaded from the workspace.
If the 7-segment display shows something else, it is not necessary to download the
text file and the download is complete.
Activate text download:
Select Text with a right mouse click and choose Set as Active Project from the
pop up menu
4
3
2
1
S5