196
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
13.27 ConvModeAI6 (conversion mode analog input 6)
The distinction between bipolar and unipolar respectively voltage and current is done via DIP-switches on the
RAIO-01 board:
0 =
±
10V Bi
-10 V to 10 V / -20 mA to 20 mA bipolar input, default
1 = 0V-10V Uni
0 V to 10 V / 0 mA to 20 mA unipolar input
2 = 2V-10V Uni
2 V to 10 V / 4 mA to 20 mA unipolar input
3 = 5V Offset
5 V / 10 mA offset in the range 0 V to 10 V / 0 mA to 20 mA for testing or indication of
bipolar signals (e.g. torque, speed, etc.)
4 = 6V Offset
6 V / 12 mA offset in the range 2 V to 10 V / 4 mA to 20 mA for testing or indication of
bipolar signals (e.g. torque, speed, etc.)
Int. Scaling: 1 == 1
Type: C
Volatile:
N
±
1
0
V Bi
6
V
O
ffs
e
t
±
1
0
V Bi
-
Group 14: Digital outputs
14.01 DO1Index (digital output 1 index)
Digital output 1 is controlled by a selectable bit - see DO1BitNo (14.02) - of the source (signal/parameter)
selected with this parameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Examples:
−
If DO1Index (14.01) = 801 (main status word) and DO1BitNo (14.02) = 1 (RdyRun) digital output 1 is high
when the drive is RdyRun.
−
If DO1Index (14.01) = -801 (main status word) and DO1BitNo (14.02) = 3 (Tripped) digital output 1 is high
when the drive is not faulty.
Digital output 1 default setting is: command FansOn CurCtrlStat1 (6.03) bit 0.
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
603
-
14.02 DO1BitNo (digital output 1 bit number)
Bit number of the signal/parameter selected with DO1Index (14.02).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
0
-
14.03 DO2Index (digital output 2 index)
Digital output 2 is controlled by a selectable bit - see DO2BitNo (14.04) - of the source (signal/parameter)
selected with this parameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
0
-
14.04 DO2BitNo (digital output 2 bit number)
Bit number of the signal/parameter selected with DO2Index (14.03).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
0
-
14.05 DO3Index (digital output 3 index)
Digital output 3 is controlled by a selectable bit - see DO3BitNo (14.06) - of the source (signal/parameter)
selected with this parameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Digital output 3 default setting is: command MainContactorOn CurCtrlStat1 (6.03) bit 7.
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
603
-
14.06 DO3BitNo (digital output 3 bit number)
Bit number of the signal/parameter selected with DO3Index (14.05).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
7
-
14.07 DO4Index (digital output 4 index)
Digital output 4 is controlled by a selectable bit - see DO4BitNo (14.08) - of the source (signal/parameter)
selected with this parameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
0
-
14.08 DO4BitNo (digital output 4 bit number)
Bit number of the signal/parameter selected with DO4Index (14.07).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
15
0
-
14.09 - 14.14 Unused
14.15 DO8Index (digital output 8 index)
Digital output 8 is controlled by a selectable bit - see DO8BitNo (14.16) - of the source (signal/parameter)
selected with this parameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Digital output 8 default setting is: command MainContactorOn CurCtrlStat1 (6.03) bit 7
Int. Scaling: 1 == 1
Type: SI
Volatile:
N
-9999
9999
603
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...