Chapter 1 - Introduction
DCS 500 / DCS 600 Service Manual
VI A
1 - 3
D C S 5 0 1 B 0 9 0 0 - 5 1 - 2 1 0 2 0 5 0 - 0 0 0 0 0 0 0 0 0
DC Drives
Type
S = Standard
F = Fieldexciter
Product family
50 = DCS500 converter module
60 = DCS600 converter module
Bridge type
1 = single (2-Q)
2 = double (4-Q)
Version (Salestyp)
B = modules with SDCS-CON-2
- = for all DCS600/DCF600
Type
(Rated DC 4-Q-current (IP00))
Rated AC voltage
4 = 220...400V
5 = 415...500V
6 = 525...600V
7 = 660...690V
8 = 700...830V
9 = 800...999V
1 = 1190V
Frequency
1 = 50/60 Hz
Power connection (C4 or A7)
- = no option (size C1...A6)
R = on the right
L = on the left
Option
Softwaretyp
15 = Multidrive
18 = Crane drive
21 = OEM
Control panel
0 = no panel
P = panel included
Fieldexciter
0 = no field exciter
1 = SDCS-FEX1
2 = SDCS-FEX2..
Fan voltage
0 = standard
5 = 400-500V only size A6/7
6 = 525-690V only size A6/7
Communication boards
0 = no communication board
5 = SDCS-COM5-board
A = SDCS-AMC-DCx-board
C = SDCS-AMC-DC-Clasx-board
Coated version
0 = no coating
X = coated version
Special Options
UL-approval
0 = standard module with UL-certificaion
U = modification for UL-certification (C3, A6/7)
Interfaces
0 = no fieldbus module included
Current measurement modification
0 = no modification
C = CMA-2 included
M = Paralleling Master converter
S = Paralleling Slave converter
Voltage measurement modification
0 = no modification
5 = PIN=51 modified for 500 V
6 = PIN=51 modified for 600 V
7 = PIN=51 modified for 700 V
8 = PIN=51 modified for 800 V
9 = PIN=51 modified for 1000 V
A = PIN-51 modified for 235V
B = PIN-51 modified for 120V
C = PIN-51 modified for 70V
D = PIN-51 modified for 40V
X = Galvanic Isolation
Special Customer Software
000= Standard
Design revision
Thyristor type (only for disc types)
1 = ABB Lenzburg
2 = Eupec
Design rev. index
only used for internal informations
OEM
Des.
Rev.
System
Figure 1-2
Type code
3ADW000093R0601_DCS500B/DCS600_Service Manual_e_f